Grandmaison, Gaël; Grobéty, Thomas; Vaucher, Julien; Hayoz, Daniel; Suter, Philipp (2024). Prevalence of Critical Errors and Insufficient Peak Inspiratory Flow in Patients Hospitalized with COPD in a Department of General Internal Medicine: A Cross-Sectional Study. Chronic obstructive pulmonary diseases, 11(4), pp. 406-415. COPD Foundation 10.15326/jcopdf.2024.0505
Text
JCOPDF-2024-0505-InPress.pdf - Accepted Version Restricted to registered users only Available under License Publisher holds Copyright. Download (1MB) |
BACKGROUND
The suboptimal use of inhalers in the treatment of patients with chronic obstructive pulmonary disease (COPD) is probably a major but poorly documented problem in hospitalized patients. We aimed to describe the prevalence of misused inhalers among patients hospitalized with COPD in a department of general internal medicine.
METHODS
We conducted a monocentric cross-sectional study in consecutive patients with a diagnosis of COPD and hospitalized between August 2022 and April 2023 in the internal medicine division of Fribourg Hospital, Switzerland. Patients underwent an assessment of their inhaler technique and peak inspiratory flow (PIF) using the In-Check Dial G16®. The primary outcome was the prevalence of misused inhalers, defined as an inhaler used with a critical error and/or insufficient PIF. Secondary outcomes included the prevalence of inhaler unsuitable to patient characteristics and of patients using at least one misused inhaler.
RESULTS
The study included 96 patients and 160 inhalers were assessed at admission. Among these inhalers, 111 (69.4%; 95% confidence interval [CI] 61.6-76.4) were misused; 105 (65.6%; 95% CI 57.7-72.9) due to the presence of a critical error in the inhalation technique and 22 (13.8%; 95% CI 8.8-20.1) due to insufficient PIF. Concerning the secondary outcome, 27 inhalers (16.9%) were unsuitable and 79 patients (82.3%) used at least one misused inhaler.
CONCLUSION
Among patients hospitalized with a diagnosis of COPD, two-thirds of inhalers were misused. Suboptimal use was mainly due to the presence of critical errors, but also to the presence of an insufficient PIF and unsuitable inhalers.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Gastro-intestinal, Liver and Lung Disorders (DMLL) > Clinic of Pneumology |
UniBE Contributor: |
Suter, Philipp |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
2372-952X |
Publisher: |
COPD Foundation |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
25 Jun 2024 11:27 |
Last Modified: |
27 Jul 2024 00:15 |
Publisher DOI: |
10.15326/jcopdf.2024.0505 |
PubMed ID: |
38901836 |
Uncontrolled Keywords: |
chronic obstructive pulmonary disease critical error hospital inhaler peak inspiratory flow |
BORIS DOI: |
10.48350/197983 |
URI: |
https://boris.unibe.ch/id/eprint/197983 |