Paravalvular leak closure after TAVI with plugs: A literature review with a specific focus on arterio-arterial loop.

Flores-Umanzor, Eduardo; Cepas-Guillén, Pedro; Ruberti, Andrea; Regueiro, Ander; Sanchis, Laura; Gabani, Rami; Rodés-Cabau, Josep; Vidal, Barbara; Freixa, Xavier (2024). Paravalvular leak closure after TAVI with plugs: A literature review with a specific focus on arterio-arterial loop. (In Press). Catheterization and cardiovascular interventions: official journal of the Society for Cardiac Angiography & Interventions Wiley 10.1002/ccd.31145

[img] Text
Cathet_Cardio_Intervent_-_2024_-_Flores_Umanzor_-_Paravalvular_leak_closure_after_TAVI_with_plugs__A_literature_review_with.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

More than mild paravalvular leak (PVL) following transcatheter aortic valve implantation (TAVI) is associated with a twofold increase in all-cause mortality, heart failure hospitalizations, and the need for reintervention. Successfully addressing PVL in TAVIs is more challenging than in surgical valves. The arterial-arterial (A-A) rail technique emerges as a valuable strategy for post-TAVI PVL closure, enhancing success rates by enabling the effective use of lower-profile vascular plug devices. When standard approach is ineffective, generating an A-A loop for post-TAVI PVL closure is probably the most recommended strategy to ensure procedural success.

Item Type:

Journal Article (Review Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Ruberti, Andrea Alberto

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1522-726X

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

11 Jul 2024 08:25

Last Modified:

12 Jul 2024 05:18

Publisher DOI:

10.1002/ccd.31145

PubMed ID:

38984656

Uncontrolled Keywords:

arterial‐arterial rail technique paravalvular leakage transcatheter aortic valve implantations

BORIS DOI:

10.48350/198901

URI:

https://boris.unibe.ch/id/eprint/198901

Actions (login required)

Edit item Edit item
Provide Feedback