Effect of immediate all-digital restoration of single posterior implants: The SafetyCrown concept on patient-reported outcome measures, accuracy, and treatment time-A randomized clinical trial.

Waltenberger, Lukas; Reich, Sven; Zwahlen, Marcel; Wolfart, Stefan (2024). Effect of immediate all-digital restoration of single posterior implants: The SafetyCrown concept on patient-reported outcome measures, accuracy, and treatment time-A randomized clinical trial. (In Press). Clinical implant dentistry and related research Blackwell 10.1111/cid.13374

[img]
Preview
Text
Clin_Implant_Dent_Rel_Res_-_2024_-_Waltenberger_-_Effect_of_immediate_all_digital_restoration_of_single_posterior_implants_.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial (CC-BY-NC).

Download (3MB) | Preview

OBJECTIVE

The SafetyCrown workflow facilitates the immediate restoration of posterior single sites with the one-abutment/one-time concept. This randomized clinical trial aimed to assess the direct effect of immediate restoration on dental patient-reported outcomes (dPROs), feasibility, implant accuracy, and time.

MATERIALS AND METHODS

Participants with a single posterior edentulous site for late implant placement underwent optical impressions, shade selection, and cone beam computed tomography. After virtual treatment planning, they were randomized into the test group and the control group. For the test group, individual definitive hybrid abutments were prefabricated. The next step was a fully guided surgery with printed guides. After the implant was placed using guided surgery, the abutment was inserted. A chairside CAD/CAM workflow was used to provide the patient with a provisional restoration. Implants in the control group were left submerged to heal. Oral health-related quality of life (OHRQoL) was assessed using the OHIP-G14, and dPRO was measured using a 10-item visual analog scale (VAS) questionnaire. Additional measurements of implant accuracy and time were performed. Follow-up was performed 7 to 10 days after implant placement.

RESULTS

Thirty-nine participants with 45 restorations were included (test group: 23, control: 22). Immediate restoration was successful in 21 out of 23 implants (91.3%) in the test group. Both groups exhibited decreased OHRQoL without significant intergroup differences, while patient satisfaction was high overall. Test group participants perceived higher benefits and satisfaction with immediate loading than participants in the control group. Implant accuracy averaged 0.60 mm at the shoulder and 0.95 mm at the apex. Operative time was longer in the immediate loading group (61.9 min) than in the control group (32.1 min) (p < 0.001).

CONCLUSIONS

Considering the limitations, the immediate restoration of late placed posterior implants using the described workflow proved feasible in 21 out of 23 cases. Both groups achieved high patient satisfaction with no differences in OHRQoL during the first week. Patients who received immediate loading rated the benefits very highly and were satisfied with the provisional restoration during the healing period.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM)

UniBE Contributor:

Zwahlen, Marcel

Subjects:

600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services

ISSN:

1523-0899

Publisher:

Blackwell

Language:

English

Submitter:

Pubmed Import

Date Deposited:

21 Aug 2024 10:48

Last Modified:

22 Aug 2024 15:20

Publisher DOI:

10.1111/cid.13374

PubMed ID:

39161052

Uncontrolled Keywords:

CAD/CAM OHRQoL PROM guided surgery immediate restoration one‐abutment/one‐time single implants time assessment

BORIS DOI:

10.48350/199854

URI:

https://boris.unibe.ch/id/eprint/199854

Actions (login required)

Edit item Edit item
Provide Feedback