Diagnostic efficacy of SonoVue, a second generation contrast agent, in the assessment of extracranial carotid or peripheral arteries using colour and spectral Doppler ultrasound: a multicentre study

Sidhu, P S; Allan, P L; Cattin, F; Cosgrove, D O; Davies, A H; Do, D D; Karakagil, S; Langholz, J; Legemate, D A; Martegani, A; Llull, J-B; Pezzoli, C; Spinazzi, A (2006). Diagnostic efficacy of SonoVue, a second generation contrast agent, in the assessment of extracranial carotid or peripheral arteries using colour and spectral Doppler ultrasound: a multicentre study. British journal of radiology, 79(937), pp. 44-51. London: British Institute of Radiology 10.1259/bjr/23954854

Full text not available from this repository. (Request a copy)

The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Angiology

UniBE Contributor:

Do, Dai-Do

ISSN:

0007-1285

ISBN:

16421404

Publisher:

British Institute of Radiology

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 14:49

Last Modified:

05 Dec 2022 14:15

Publisher DOI:

10.1259/bjr/23954854

PubMed ID:

16421404

Web of Science ID:

000235007600008

URI:

https://boris.unibe.ch/id/eprint/20649 (FactScience: 4324)