Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts

Bonel, H; Frei, K A; Raio, L; Meyer-Wittkopf, M; Remonda, L; Wiest, R (2008). Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts. European radiology, 18(4), pp. 822-9. Berlin: Springer-Verlag 10.1007/s00330-007-0812-x

[img]
Preview
Text
330_2007_Article_812.pdf - Published Version
Available under License Publisher holds Copyright.

Download (281kB) | Preview

The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 +/- 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 +/- 0.58 vs. 3.65 +/- 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 +/- 7.27 to 19.83 +/- 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology
04 Faculty of Medicine > Department of Gynaecology, Paediatrics and Endocrinology (DFKE) > Clinic of Gynaecology
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic and Interventional Neuroradiology

UniBE Contributor:

Bonel, Harald Marcel, Frei Bonel, Kathrin Anne, Raio, Luigi, Meyer-Wittkopf, Matthias, Remonda, Luca, Wiest, Roland Gerhard Rudi

ISSN:

0938-7994

ISBN:

18075742

Publisher:

Springer-Verlag

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 14:54

Last Modified:

02 Mar 2023 23:22

Publisher DOI:

10.1007/s00330-007-0812-x

PubMed ID:

18075742

Web of Science ID:

000254235900025

BORIS DOI:

10.7892/boris.23051

URI:

https://boris.unibe.ch/id/eprint/23051 (FactScience: 38724)

Actions (login required)

Edit item Edit item
Provide Feedback