Hausler, R; Stieger, C; Bernhard, H; Kompis, M (2008). A Novel Implantable Hearing System with Direct Acoustic Cochlear Stimulation. Audiology & neuro-otology, 13(4), pp. 247-256. Basel: Karger 10.1159/000115434
|
Text
000115434.pdf - Published Version Available under License Publisher holds Copyright. Download (725kB) | Preview |
A new implantable hearing system, the direct acoustic cochlear stimulator (DACS) is presented. This system is based on the principle of a power-driven stapes prosthesis and intended for the treatment of severe mixed hearing loss due to advanced otosclerosis. It consists of an implantable electromagnetic transducer, which transfers acoustic energy directly to the inner ear, and an audio processor worn externally behind the implanted ear. The device is implanted using a specially developed retromeatal microsurgical approach. After removal of the stapes, a conventional stapes prosthesis is attached to the transducer and placed in the oval window to allow direct acoustical coupling to the perilymph of the inner ear. In order to restore the natural sound transmission of the ossicular chain, a second stapes prosthesis is placed in parallel to the first one into the oval window and attached to the patient's own incus, as in a conventional stapedectomy. Four patients were implanted with an investigational DACS device. The hearing threshold of the implanted ears before implantation ranged from 78 to 101 dB (air conduction, pure tone average, 0.5-4 kHz) with air-bone gaps of 33-44 dB in the same frequency range. Postoperatively, substantial improvements in sound field thresholds, speech intelligibility as well as in the subjective assessment of everyday situations were found in all patients. Two years after the implantations, monosyllabic word recognition scores in quiet at 75 dB improved by 45-100 percent points when using the DACS. Furthermore, hearing thresholds were already improved by the second stapes prosthesis alone by 14-28 dB (pure tone average 0.5-4 kHz, DACS switched off). No device-related serious medical complications occurred and all patients have continued to use their device on a daily basis for over 2 years. Copyright (c) 2008 S. Karger AG, Basel.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Ear, Nose and Throat Disorders (ENT) |
UniBE Contributor: |
Häusler, Rudolf, Kompis, Martin |
ISSN: |
1420-3030 |
ISBN: |
18259077 |
Publisher: |
Karger |
Language: |
English |
Submitter: |
Factscience Import |
Date Deposited: |
04 Oct 2013 14:56 |
Last Modified: |
24 May 2023 19:29 |
Publisher DOI: |
10.1159/000115434 |
PubMed ID: |
18259077 |
Web of Science ID: |
000255895800005 |
BORIS DOI: |
10.48350/23716 |
URI: |
https://boris.unibe.ch/id/eprint/23716 (FactScience: 43690) |