Second international collaborative study evaluating performance characteristics of methods measuring the von Willebrand factor cleaving protease (ADAMTS-13)

Tripodi, A; Peyvandi, F; Chantarangkul, V; Palla, R; Afrasiabi, A; Canciani, M T; Chung, D W; Ferrari, S; Fujimura, Y; Karimi, M; Kokame, K; Kremer Hovinga, J A; Lämmle, B; de Meyer, S F; Plaimauer, B; Vanhoorelbeke, K; Varadi, K; Mannucci, P M (2008). Second international collaborative study evaluating performance characteristics of methods measuring the von Willebrand factor cleaving protease (ADAMTS-13). Journal of thrombosis and haemostasis, 6(9), pp. 1534-41. Oxford: Blackwell 10.1111/j.1538-7836.2008.03099.x

Full text not available from this repository.

BACKGROUND: Over the last 4 years ADAMTS-13 measurement underwent dramatic progress with newer and simpler methods. AIMS: Blind evaluation of newer methods for their performance characteristics. DESIGN: The literature was searched for new methods and the authors invited to join the evaluation. Participants were provided with a set of 60 coded frozen plasmas that were prepared centrally by dilutions of one ADAMTS-13-deficient plasma (arbitrarily set at 0%) into one normal-pooled plasma (set at 100%). There were six different test plasmas ranging from 100% to 0%. Each plasma was tested 'blind' 10 times by each method and results expressed as percentage vs. the local and the common standard provided by the organizer. RESULTS: There were eight functional and three antigen assays. Linearity of observed-vs.-expected ADAMTS-13 levels assessed as r2 ranged from 0.931 to 0.998. Between-run reproducibility expressed as the (mean) CV for repeated measurements was below 10% for three methods, 10-15% for five methods and up to 20% for the remaining three. F-values (analysis of variance) calculated to assess the capacity to distinguish between ADAMTS-13 levels (the higher the F-value, the better the capacity) ranged from 3965 to 137. Between-method variability (CV) amounted to 24.8% when calculated vs. the local and to 20.5% when calculated vs. the common standard. Comparative analysis showed that functional assays employing modified von Willebrand factor peptides as substrate for ADAMTS-13 offer the best performance characteristics. CONCLUSIONS: New assays for ADAMTS-13 have the potential to make the investigation/management of patients with thrombotic microangiopathies much easier than in the past.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Haematology and Central Haematological Laboratory

UniBE Contributor:

Kremer Hovinga Strebel, Johanna Anna, Lämmle, Bernhard

ISSN:

1538-7933

ISBN:

18662260

Publisher:

Blackwell

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 15:02

Last Modified:

02 Mar 2023 23:22

Publisher DOI:

10.1111/j.1538-7836.2008.03099.x

PubMed ID:

18662260

Web of Science ID:

000258471800016

URI:

https://boris.unibe.ch/id/eprint/26906 (FactScience: 97190)

Actions (login required)

Edit item Edit item
Provide Feedback