Flow impairment during protected carotid artery stenting: impact of filter device design

Roffi, Marco; Greutmann, Matthias; Schwarz, Urs; Luscher, Thomas F; Eberli, Franz R; Amann-Vesti, Beatrice (2008). Flow impairment during protected carotid artery stenting: impact of filter device design. Journal of endovascular therapy, 15(1), pp. 103-9. Phoenix, Ariz.: International Society of Endovascular Specialists 10.1583/07-2252.1

Full text not available from this repository. (Request a copy)

PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Eberli, Franz

ISSN:

1526-6028

ISBN:

18254671

Publisher:

International Society of Endovascular Specialists

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 15:02

Last Modified:

05 Dec 2022 14:19

Publisher DOI:

10.1583/07-2252.1

PubMed ID:

18254671

Web of Science ID:

000253060300014

URI:

https://boris.unibe.ch/id/eprint/26946 (FactScience: 99183)

Actions (login required)

Edit item Edit item
Provide Feedback