Drug eluting and bare metal stents in people with and without diabetes: collaborative network meta-analysis

Stettler, Christoph; Allemann, Sabin; Wandel, Simon; Kastrati, Adnan; Morice, Marie Claude; Schömig, Albert; Pfisterer, Matthias E; Stone, Gregg W; Leon, Martin B; de Lezo, José Suárez; Goy, Jean-Jacques; Park, Seung-Jung; Sabaté, Manel; Suttorp, Maarten J; Kelbaek, Henning; Spaulding, Christian; Menichelli, Maurizio; Vermeersch, Paul; Dirksen, Maurits T; Cervinka, Pavel; ... (2008). Drug eluting and bare metal stents in people with and without diabetes: collaborative network meta-analysis. BMJ, 337(11), a1331. London: BMJ Publishing Group 10.1136/bmj.a1331

[img]
Preview
Text
Stettler BritMedJ 2008.pdf - Published Version
Available under License Publisher holds Copyright.

Download (488kB) | Preview

Objective

To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus.

Design

Collaborative network meta-analysis.

Data sources

Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data.

Review methods

Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point.

Results

35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes.

Conclusion

In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Gynaecology, Paediatrics and Endocrinology (DFKE) > Clinic of Endocrinology, Diabetology and Clinical Nutrition
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM)
04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Stettler, Christoph, Allemann, Sabin, Wandel, Simon, Diem, Peter, Meier, Bernhard, Windecker, Stephan, Jüni, Peter

ISSN:

1756-1833

ISBN:

18757996

Publisher:

BMJ Publishing Group

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 15:02

Last Modified:

05 Dec 2022 14:19

Publisher DOI:

10.1136/bmj.a1331

PubMed ID:

18757996

Web of Science ID:

000259622000030

BORIS DOI:

10.7892/boris.26982

URI:

https://boris.unibe.ch/id/eprint/26982 (FactScience: 99353)

Actions (login required)

Edit item Edit item
Provide Feedback