Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval

Piazza, Nicolo; Grube, Eberhard; Gerckens, Ulrich; den Heijer, Peter; Linke, Axel; Luha, Olev; Ramondo, Angelo; Ussia, Giampaolo; Wenaweser, Peter; Windecker, Stephan; Laborde, Jean-Claude; de Jaegere, Peter; Serruys, Patrick W (2008). Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention, 4(2), pp. 242-9. Toulouse: Europa Digital & Publishing 10.4244/EIJV4I2A43

Full text not available from this repository.

AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Wenaweser, Peter Martin, Windecker, Stephan

ISSN:

1774-024X

ISBN:

19110790

Publisher:

Europa Digital & Publishing

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 15:02

Last Modified:

05 Dec 2022 14:19

Publisher DOI:

10.4244/EIJV4I2A43

PubMed ID:

19110790

Web of Science ID:

000260094700015

URI:

https://boris.unibe.ch/id/eprint/27008 (FactScience: 99672)

Actions (login required)

Edit item Edit item
Provide Feedback