Longitudinal evaluation of cartilage composition of matrix-associated autologous chondrocyte transplants with 3-T delayed gadolinium-enhanced MRI of cartilage

Pinker, K; Szomolanyi, P; Welsch, GC; Mamisch, TC; Marlovits, S; Stadlbauer, A; Trattnig, S (2008). Longitudinal evaluation of cartilage composition of matrix-associated autologous chondrocyte transplants with 3-T delayed gadolinium-enhanced MRI of cartilage. AJR, American journal of roentgenology, 191(5), pp. 1391-6. Leesburg, Va.: American Roentgen Ray Society 10.2214/AJR.07.3930

Full text not available from this repository.

OBJECTIVE: The purposes of this study were to use delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) to evaluate the zonal distribution of glycosaminoglycans (GAGs) in normal cartilage and repair tissue and to use 3-T MRI to monitor the GAG content in matrix-associated autologous chondrocyte transplants. SUBJECTS AND METHODS: Fifteen patients who underwent matrix-associated autologous chondrocyte transplantation in the knee joint underwent MRI at baseline and 3-T follow-up MRI 1 year later. Total and zonal changes in longitudinal relaxivity (deltaR1) and relative deltaR1 were calculated for repair tissue and normal hyaline cartilage and compared by use of analysis of variance. RESULTS: There was a significant difference between the mean deltaR1 of repair tissue and that of reference cartilage at baseline and follow-up (p < 0.001). There was a significant increase in deltaR1 value and a decrease in GAG content from the deep layer to the superficial layer in the reference cartilage and almost no variation and significantly higher values for the repair tissue at both examinations. At 1-year follow-up imaging, there was a 22.7% decrease in deltaR1 value in the deep zone of the transplant. CONCLUSION: T1 mapping with dGEMRIC at 3 T shows the zonal structure of normal hyaline cartilage, highly reduced zonal variations in repair tissue, and a tendency toward an increase in global and zonal GAG content 1 year after transplantation.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Orthopaedic, Plastic and Hand Surgery (DOPH) > Clinic of Orthopaedic Surgery

UniBE Contributor:

Mamisch, Tallal Charles

ISSN:

0361-803X

ISBN:

18941075

Publisher:

American Roentgen Ray Society

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 15:03

Last Modified:

05 Dec 2022 14:19

Publisher DOI:

10.2214/AJR.07.3930

PubMed ID:

18941075

Web of Science ID:

000260246700017

URI:

https://boris.unibe.ch/id/eprint/27465 (FactScience: 107813)

Actions (login required)

Edit item Edit item
Provide Feedback