Torque expression of 0.018 and 0.022 inch conventional brackets

Sifakakis, Iosif; Pandis, Nikolaos; Makou, Margarita; Eliades, Theodore; Katsaros, Christos; Bourauel, Christoph (2013). Torque expression of 0.018 and 0.022 inch conventional brackets. European journal of orthodontics, 35(5), pp. 610-4. Oxford University Press 10.1093/ejo/cjs041

[img]
Preview
Text
610.full.pdf - Published Version
Available under License Publisher holds Copyright.

Download (324kB) | Preview

The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Orthodontics

UniBE Contributor:

Pandis, Nikolaos, Eliades, Theodore, Katsaros, Christos

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0141-5387

Publisher:

Oxford University Press

Language:

English

Submitter:

Eveline Carmen Schuler

Date Deposited:

28 Jan 2014 08:30

Last Modified:

19 Dec 2022 11:05

Publisher DOI:

10.1093/ejo/cjs041

PubMed ID:

22828075

BORIS DOI:

10.7892/boris.39990

URI:

https://boris.unibe.ch/id/eprint/39990

Actions (login required)

Edit item Edit item
Provide Feedback