Comparison of Newer-Generation Drug-Eluting With Bare-Metal Stents in Patients With Acute ST-Segment Elevation Myocardial Infarction: A Pooled Analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) Trials

Sabaté, Manel; Räber, Lorenz; Heg, Dik; Brugaletta, Salvatore; Kelbaek, Henning; Cequier, Angel; Ostojic, Miodrag; Iñiguez, Andrés; Tüller, David; Serra, Antonio; Baumbach, Andreas; von Birgelen, Clemens; Hernandez-Antolin, Rosana; Roffi, Marco; Mainar, Vicente; Valgimigli, Marco; Serruys, Patrick W; Jüni, Peter; Windecker, Stephan (2014). Comparison of Newer-Generation Drug-Eluting With Bare-Metal Stents in Patients With Acute ST-Segment Elevation Myocardial Infarction: A Pooled Analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) Trials. JACC. Cardiovascular Interventions, 7(1), pp. 55-63. Elsevier 10.1016/j.jcin.2013.07.012

[img] Text
Sabate JACCCardiovascInterv 2014.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB)

OBJECTIVES
This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI).

BACKGROUND
Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES.

METHODS
Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year.

RESULTS
Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS.

CONCLUSIONS
Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > Department of Clinical Research (DCR)
04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Kardiologie
04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Kardiologie

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM)

UniBE Contributor:

Räber, Lorenz, Heg, Dierik Hans, Jüni, Peter, Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services

ISSN:

1876-7605

Publisher:

Elsevier

Language:

English

Submitter:

Doris Kopp Heim

Date Deposited:

06 Mar 2014 22:19

Last Modified:

20 Feb 2024 14:17

Publisher DOI:

10.1016/j.jcin.2013.07.012

PubMed ID:

24332419

Uncontrolled Keywords:

BES BMS CI DES DOCE EES HR POCE RR ST-segment elevation myocardial infarction STEMI bare-metal stent(s) biolimus A9–eluting stent(s) confidence interval device-oriented composite endpoint drug-eluting stent(s) everolimus-eluting stent(s) hazard ratio patient-oriented composite endpoint relative risk stent thrombosis