Radu, Maria D.; Räber, Lorenz; Kalesan, Bindu; Muramatsu, Takashi; Kelbæk, Henning; Heo, Jungho; Jørgensen, Erik; Helqvist, Steffen; Farooq, Vasim; Brugaletta, Salvatore; Garcia-Garcia, Hector M.; Jüni, Peter; Saunamäki, Kari; Windecker, Stephan; Serruys, Patrick W. (2014). Coronary evaginations are associated with positive vessel remodelling and are nearly absent following implantation of newer-generation drug-eluting stents: an optical coherence tomography and intravascular ultrasound study. European Heart Journal, 35(12), pp. 795-8. Oxford University Press 10.1093/eurheartj/eht344
|
Text
Radu EurHeartJ 2014.pdf - Published Version Available under License Publisher holds Copyright. Download (975kB) | Preview |
OBJECTIVES
The purpose of this study was to assess the occurrence, predictors, and mechanisms of optical coherence tomography (OCT)-detected coronary evaginations following drug-eluting stent (DES) implantation.
BACKGROUND
Angiographic ectasias and aneurysms in stented segments have been associated with a risk of late stent thrombosis. Using OCT, some stented segments show coronary evaginations reminiscent of ectasias.
METHODS
Evaginations were defined as outward bulges in the luminal contour between struts. They were considered major evaginations (MEs) when extending ≥3 mm along the vessel length, with a depth ≥10% of the stent diameter. A total of 228 patients who had sirolimus (SES)-, paclitaxel-, biolimus-, everolimus (EES)-, or zotarolimus (ZES)-eluting stents implanted in 254 lesions, were analysed after 1, 2, or 5 years; and serial assessment using OCT and intravascular ultrasound (IVUS) was performed post-intervention and after 1 year in 42 patients.
RESULTS
Major evaginations occurred frequently at all time points in SES (∼26%) and were rarely seen in EES (3%) and ZES (2%, P = 0.003). Sirolimus-eluting stent implantation was the strongest independent predictor of ME [adjusted OR (95% CI) 9.1 (1.1-77.4), P = 0.008]. Malapposed and uncovered struts were more common in lesions with vs. without ME (77 vs. 25%, P < 0.001 and 95 vs. 20%, P < 0.001, respectively) as was thrombus [49 vs. 14%, OR 7.3 (95% CI: 1.7-31.2), P = 0.007]. Post-intervention intra-stent dissection and protrusion of the vessel wall into the lumen were associated with an increased risk of evagination at follow-up [OR (95% CI): 2.9 (1.8-4.9), P < 0.001 and 3.3 (1.6-6.9), P = 0.001, respectively]. In paired IVUS analyses, lesions with ME showed a larger increase in the external elastic membrane area (20% area change) compared with lesions without ME (5% area change, P < 0.001).
CONCLUSION
Optical coherence tomography-detected MEs are a specific morphological footprint of early-generation SES and are nearly absent in newer-generation ZES and EES. Evaginations appear to be related to vessel injury at baseline; are associated with positive vessel remodelling; and correlate with uncoverage, malapposition, and thrombus at follow-up.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM) 04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology |
UniBE Contributor: |
Räber, Lorenz, Kalesan, Bindu, Jüni, Peter, Windecker, Stephan |
Subjects: |
600 Technology > 610 Medicine & health 300 Social sciences, sociology & anthropology > 360 Social problems & social services |
ISSN: |
0195-668X |
Publisher: |
Oxford University Press |
Language: |
English |
Submitter: |
Doris Kopp Heim |
Date Deposited: |
24 Feb 2014 10:12 |
Last Modified: |
05 Dec 2022 14:28 |
Publisher DOI: |
10.1093/eurheartj/eht344 |
PubMed ID: |
24132187 |
Uncontrolled Keywords: |
Coronary evaginations, Early-generation drug-eluting stents, Intravascular ultrasound, Malapposition, Newer-generation drug-eluting stents, Optical coherence tomography, Positive remodelling, Uncovered stent struts |
BORIS DOI: |
10.7892/boris.41335 |
URI: |
https://boris.unibe.ch/id/eprint/41335 |