Increment thickness versus dentin bond strength of bulk fill flowables

Flury, Simon; Peutzfeldt, Anne; Lussi, Adrian (6 September 2013). Increment thickness versus dentin bond strength of bulk fill flowables. In: Continental European Division of the International Association for Dental Research (CED-IADR). Florence, Italy. 04.-07.09.2013.

[img]
Preview
Image (Poster)
CED-IADR_2013_Flury.pdf - Published Version
Available under License BORIS Standard License.

Download (4MB) | Preview

Objectives: The aim was to investigate the influence of increment thickness on shear bond strength (SBS) to dentin of a conventional and two bulk fill flowable composites.

Methods: A total of 135 specimens of ground human dentin were produced (n=15/group; 3 increment thicknesses; 3 flowable composites) and the dentin surfaces were treated with the adhesive system OptiBond FL (Kerr) according to manufacturer’s instructions. Split Teflon molds (inner diameter: 3.6 mm) of 2 mm, 4 mm, or 6 mm height allowing three increment thicknesses were clamped on the dentin surfaces and filled with either the conventional flowable Filtek Supreme XTE ((XTE); 3M ESPE) or the bulk fill flowables Filtek Bulk Fill ((FBF); 3M ESPE) or SDR ((SDR); DENTSPLY Caulk). The flowable composites were light-cured for 20 s (Demi LED; Kerr) and the specimens stored for 24 h (37°C, 100% humidity). Specimens were then subjected to a SBS-test in a universal testing machine at a cross-head speed of 1 mm/min (Zwick Z010; Zwick GmbH & Co.). SBS-values were statistically analysed with a nonparametrical ANOVA followed by exact Wilcoxon rank sum tests (α=0.05). Failure mode of the specimens was determined under a stereomicroscope at 25× magnification.

Results: SBS-values (MPa) at 2 mm/4 mm/6 mm increment thicknesses (mean value [standard deviation]) were for XTE: 18.8 [2.6]/17.6 [1.6]/16.7 [3.1], for FBF: 20.6 [2.7]/17.8 [2.7]/18.7 [2.9], and for SDR: 21.7 [2.6]/18.5 [2.6]/20.3 [3.0]. For all three flowable composites, 2 mm increments yielded the highest SBS-values whereas for increments of 4 mm and 6 mm no differences were detected. All specimens presented failure modes involving cohesive failure in dentin.

Conclusion: The influence of increment thickness on dentin SBS was less pronounced than expected. However, the high number of cohesive failures in dentin, reflecting the efficiency of the adhesive system, suggests a limited discriminatory power of the SBS-test.

Item Type:

Conference or Workshop Item (Poster)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry

UniBE Contributor:

Flury, Simon, Peutzfeldt, Anne, Lussi, Adrian

Subjects:

600 Technology > 610 Medicine & health

Language:

English

Submitter:

Simon Flury

Date Deposited:

25 Jul 2014 15:40

Last Modified:

05 Dec 2022 14:36

BORIS DOI:

10.7892/boris.54950

URI:

https://boris.unibe.ch/id/eprint/54950

Actions (login required)

Edit item Edit item
Provide Feedback