New online method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

Affolter, Stéphane; Fleitmann, D.; Leuenberger, Markus (2014). New online method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS). Climate of the past, 10(4), pp. 1291-1304. Copernicus Publications 10.5194/cp-10-1291-2014

[img]
Preview
Text
cp-10-1291-2014.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (8MB) | Preview

A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us simultaneously to measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the online water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δ D robustness.

To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water, resulting in an artificial water background with well-known δ D and δ18O values. The speleothem sample is placed in a copper tube, attached to the line, and after system stabilisation it is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements, a syringe injection unit was added to the line.

Peak evaluation is done similarly as in gas chromatography to obtain &delta D; and δ18O isotopic compositions of measured water aliquots. Precision is better than 1.5 ‰ for δ D and 0.4 ‰ for δ18O for water measurements for an extended range (−210 to 0 ‰ for δ D and −27 to 0 ‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to the isotope ratio mass spectrometry (IRMS) technique.

Item Type:

Journal Article (Original Article)

Division/Institute:

08 Faculty of Science > Physics Institute > Climate and Environmental Physics
10 Strategic Research Centers > Oeschger Centre for Climate Change Research (OCCR)

Graduate School:

Graduate School of Climate Sciences

UniBE Contributor:

Affolter, Stéphane, Leuenberger, Markus

Subjects:

500 Science > 530 Physics
500 Science > 550 Earth sciences & geology

ISSN:

1814-9324

Publisher:

Copernicus Publications

Language:

English

Submitter:

Doris Rätz

Date Deposited:

18 Aug 2014 09:56

Last Modified:

02 Mar 2023 23:25

Publisher DOI:

10.5194/cp-10-1291-2014

BORIS DOI:

10.7892/boris.57891

URI:

https://boris.unibe.ch/id/eprint/57891