Katsoulis, Joannis; Mericske, Regina; Rotkina, Lolita; Zbären, Christoph; Enkling, Norbert; Blatz, Markus B (2014). Precision of fit of implant-supported screw-retained 10-unit computer-aided-designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study. Clinical oral implants research, 25(2), pp. 165-174. Wiley-Blackwell 10.1111/clr.12039

[img] Text
Precision of fit.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (725kB)

OBJECTIVE

To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks.

MATERIALS AND METHODS

Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests.

RESULTS

No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044).

CONCLUSIONS

Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Prosthodontics [discontinued]

UniBE Contributor:

Katsoulis, Joannis, Mericske, Regina, Enkling, Norbert

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0905-7161

Publisher:

Wiley-Blackwell

Language:

English

Submitter:

Eveline Carmen Schuler

Date Deposited:

19 Jan 2015 16:58

Last Modified:

05 Dec 2022 14:39

Publisher DOI:

10.1111/clr.12039

PubMed ID:

23025489

Uncontrolled Keywords:

computer-aided design and computer-aided manufacturing, fixed partial denture, framework misfit, implant framework fit, implant-supported, passive fit, zirconium dioxide

BORIS DOI:

10.7892/boris.61744

URI:

https://boris.unibe.ch/id/eprint/61744

Actions (login required)

Edit item Edit item
Provide Feedback