Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights.

Szucs-Farkas, Zsolt; Megyeri, Boglarka; Christe, Andreas; Vock, Peter; Heverhagen, Johannes T; Schindera, Sebastian T (2014). Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights. European radiology, 24(8), pp. 1868-1877. Springer 10.1007/s00330-014-3208-8

[img]
Preview
Text
art%3A10.1007%2Fs00330-014-3208-8.pdf - Published Version
Available under License Publisher holds Copyright.

Download (597kB) | Preview

OBJECTIVES

To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA.

METHODS

In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups.

RESULTS

Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0).

CONCLUSIONS

Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg.

KEY POINTS

• 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

Christe, Andreas

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0938-7994

Publisher:

Springer

Language:

English

Submitter:

Aisha Stefania Mzinga

Date Deposited:

01 May 2015 15:25

Last Modified:

05 Dec 2022 14:45

Publisher DOI:

10.1007/s00330-014-3208-8

PubMed ID:

24865694

BORIS DOI:

10.7892/boris.66801

URI:

https://boris.unibe.ch/id/eprint/66801

Actions (login required)

Edit item Edit item
Provide Feedback