Ereditato, Antonio; Göldi, Damian; Rudolf von Rohr, Christoph; Schenk, Michael; Strauss, Thomas; Weber, Michael; Zeller, Marcel (2014). Performance of cryogenic charge readout electronics with the ARGONTUBE LAr TPC. Journal of instrumentation, 9(11), P11022. Institute of Physics Publishing IOP 10.1088/1748-0221/9/11/P11022
|
Text
BORIS_68745.pdf - Accepted Version Available under License Publisher holds Copyright. Download (10MB) | Preview |
|
Text
pdf.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (8MB) |
ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron drift length of up to 5 m equipped with cryogenic charge-sensitive preamplifiers. In this work, we
present results on its performance, including a comparison of the new cryogenic charge-sensitive preamplifiers with the previously used room-temperature-operated charge preamplifiers.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
10 Strategic Research Centers > Albert Einstein Center for Fundamental Physics (AEC) 08 Faculty of Science > Physics Institute > Laboratory for High Energy Physics (LHEP) |
UniBE Contributor: |
Ereditato, Antonio, Göldi, Damian, Rudolf von Rohr, Christoph, Schenk, Michael, Strauss, Thomas, Weber, Michele, Zeller, Marcel |
Subjects: |
500 Science > 530 Physics |
ISSN: |
1748-0221 |
Publisher: |
Institute of Physics Publishing IOP |
Language: |
English |
Submitter: |
Jan Dirk Brinksma |
Date Deposited: |
01 Jun 2015 16:13 |
Last Modified: |
05 Dec 2022 14:47 |
Publisher DOI: |
10.1088/1748-0221/9/11/P11022 |
ArXiv ID: |
1408.7046.v2 |
BORIS DOI: |
10.7892/boris.68745 |
URI: |
https://boris.unibe.ch/id/eprint/68745 |