Zeller, Thomas; Baumgartner, Iris; Scheinert, Dierk; Brodmann, Marianne; Bosiers, Marc; Micari, Antonio; Peeters, Patrick; Vermassen, Frank; Landini, Mario; Snead, David B; Kent, K Craig; Rocha-Singh, Krishna J (2014). Drug-eluting balloon versus standard balloon angioplasty for infrapopliteal arterial revascularization in critical limb ischemia: 12-month results from the IN.PACT DEEP randomized trial. Journal of the American College of Cardiology, 64(15), pp. 1568-1576. Elsevier 10.1016/j.jacc.2014.06.1198
Text
1-s2.0-S0735109714057143-main.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (544kB) |
BACKGROUND
Drug-eluting balloons (DEB) may reduce infrapopliteal restenosis and reintervention rates versus percutaneous transluminal angioplasty (PTA) and improve wound healing/limb preservation.
OBJECTIVES
The goal of this clinical trial was to assess the efficacy and safety of IN.PACT Amphirion drug-eluting balloons (IA-DEB) compared to PTA for infrapopliteal arterial revascularization in patients with critical limb ischemia (CLI).
METHODS
Within a prospective, multicenter, randomized, controlled trial with independent clinical event adjudication and angiographic and wound core laboratories 358 CLI patients were randomized 2:1 to IA-DEB or PTA. The 2 coprimary efficacy endpoints through 12 months were clinically driven target lesion revascularization (CD-TLR) and late lumen loss (LLL). The primary safety endpoint through 6 months was a composite of all-cause mortality, major amputation, and CD-TLR.
RESULTS
Clinical characteristics were similar between the 2 groups. Significant baseline differences between the IA-DEB and PTA arms included mean lesion length (10.2 cm vs. 12.9 cm; p = 0.002), impaired inflow (40.7% vs. 28.8%; p = 0.035), and previous target limb revascularization (32.2% vs. 21.8%; p = 0.047). Primary efficacy results of IA-DEB versus PTA were CD-TLR of 9.2% versus 13.1% (p = 0.291) and LLL of 0.61 ± 0.78 mm versus 0.62 ± 0.78 mm (p = 0.950). Primary safety endpoints were 17.7% versus 15.8% (p = 0.021) and met the noninferiority hypothesis. A safety signal driven by major amputations through 12 months was observed in the IA-DEB arm versus the PTA arm (8.8% vs. 3.6%; p = 0.080).
CONCLUSIONS
In patients with CLI, IA-DEB had comparable efficacy to PTA. While primary safety was met, there was a trend towards an increased major amputation rate through 12 months compared to PTA. (Study of IN.PACT Amphirion™ Drug Eluting Balloon vs. Standard PTA for the Treatment of Below the Knee Critical Limb Ischemia [INPACT-DEEP]; NCT00941733).
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Angiology |
UniBE Contributor: |
Baumgartner, Iris |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
0735-1097 |
Publisher: |
Elsevier |
Language: |
English |
Submitter: |
Catherine Gut |
Date Deposited: |
03 Jul 2015 11:20 |
Last Modified: |
05 Dec 2022 14:48 |
Publisher DOI: |
10.1016/j.jacc.2014.06.1198 |
PubMed ID: |
25301459 |
Uncontrolled Keywords: |
critical limb ischemia; drug-eluting balloon; peripheral vascular disease |