Comparison of peak cardiopulmonary performance parameters on a robotics-assisted tilt table, a cycle and a treadmill

Saengsuwan, Jittima; Nef, Tobias; Laubacher, Marco; Hunt, J. Kenneth (2015). Comparison of peak cardiopulmonary performance parameters on a robotics-assisted tilt table, a cycle and a treadmill. PLoS ONE, 10(4), e0122767. Public Library of Science 10.1371/journal.pone.0122767

[img]
Preview
Text
http___www.plosone.org_article_fetchObject.action_uri=info_doi_10.1371_journal.pone.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (468kB) | Preview

Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.

Item Type:

Journal Article (Original Article)

Division/Institute:

10 Strategic Research Centers > ARTORG Center for Biomedical Engineering Research > ARTORG Center - Gerontechnology and Rehabilitation
10 Strategic Research Centers > ARTORG Center for Biomedical Engineering Research

UniBE Contributor:

Saengsuwan, Jittima, Nef, Tobias

Subjects:

500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering

ISSN:

1932-6203

Publisher:

Public Library of Science

Language:

English

Submitter:

Vanessa Vallejo

Date Deposited:

13 Jul 2015 13:41

Last Modified:

05 Dec 2022 14:48

Publisher DOI:

10.1371/journal.pone.0122767

PubMed ID:

25860019

BORIS DOI:

10.7892/boris.70237

URI:

https://boris.unibe.ch/id/eprint/70237

Actions (login required)

Edit item Edit item
Provide Feedback