Determination of vertebral range of motion using inertial measurement units in 27 Franches-Montagnes stallions and comparison between conditions and with a mixed population

Heim, Corsin; Pfau, T.; Gerber, Vinzenz; Schweizer, Charlotte; Doherr, Marcus; Schüpbach, Gertraud; Witte, Stefan (2015). Determination of vertebral range of motion using inertial measurement units in 27 Franches-Montagnes stallions and comparison between conditions and with a mixed population. Equine veterinary journal, 48(4), pp. 509-516. Wiley-Blackwell 10.1111/evj.12455

[img]
Preview
Text
Heim_et_al-2015-Equine_Veterinary_Journal (1).pdf - Accepted Version
Available under License Publisher holds Copyright.

Download (344kB) | Preview

REASONS FOR PERFORMING STUDY:
The diagnosis of equine back disorders is challenging. Objectively determining movement of the vertebral column may therefore be of value in a clinical setting.

OBJECTIVES:
To establish whether surface-mounted inertial measurement units (IMUs) can be used to establish normal values for range of motion (ROM) of the vertebral column in a uniform population of horses trotting under different conditions.

STUDY DESIGN:
Vertebral ROM was established in Franches-Montagnes stallions and a general population of horses and the variability in measurements compared between the two groups. Repeatability and the influence of specific exercise condition (on ROM) were assessed. Finally, attempts were made to explain the findings of the study through the evaluation of factors that might influence ROM.

METHODS:
Dorsoventral (DV) and mediolateral (ML) vertebral ROM was measured at a trot under different exercise conditions in 27 Franches-Montagnes stallions and six general population horses using IMUs distributed over the vertebral column.

RESULTS:
Variability in the ROM measurements was significantly higher for general population horses than for Franches-Montagnes stallions (both DV and ML ROM). Repeatability was strong to very strong for DV measurements and moderate for ML measurements. Trotting under saddle significantly reduced the ROM, with sitting trot resulting in a significantly lower ROM than rising trot. Age is unlikely to explain the low variability in vertebral ROM recorded in the Franches-Montagnes horses, while this may be associated with conformational factors.

CONCLUSIONS:
It was possible to establish a normal vertebral ROM for a group of Franches-Montagnes stallions. While within-breed variation was low in this population, further studies are necessary to determine variation in vertebral ROM for other breeds and to assess their utility for diagnosis of equine back disorders.

Item Type:

Journal Article (Original Article)

Division/Institute:

05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > ISME Equine Clinic Bern > ISME Equine Clinic, Internal medicine
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV)
05 Veterinary Medicine > Department of Clinical Research and Veterinary Public Health (DCR-VPH) > Veterinary Public Health Institute
05 Veterinary Medicine > Department of Clinical Research and Veterinary Public Health (DCR-VPH)

UniBE Contributor:

Heim, Corsin, Gerber, Vinzenz, Schweizer, Charlotte, Doherr, Marcus, Schüpbach-Regula, Gertraud Irene, Witte, Stefan

Subjects:

600 Technology > 630 Agriculture

ISSN:

0425-1644

Publisher:

Wiley-Blackwell

Language:

English

Submitter:

Andrea Gassmann-Suter

Date Deposited:

06 Nov 2015 08:10

Last Modified:

02 Mar 2023 23:26

Publisher DOI:

10.1111/evj.12455

PubMed ID:

25919410

Uncontrolled Keywords:

back; horse; inertial measurement unit; objective; range of motion; vertebral column

BORIS DOI:

10.7892/boris.72557

URI:

https://boris.unibe.ch/id/eprint/72557

Actions (login required)

Edit item Edit item
Provide Feedback