Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian (2011). Quality evaluation of tandem mass spectral libraries. Analytical and bioanalytical chemistry, 400(8), pp. 2641-8. Heidelberg: Springer 10.1007/s00216-010-4598-3
|
Text
Oberacher2011_Article_QualityEvaluationOfTandemMassS.pdf - Published Version Available under License Publisher holds Copyright. Download (393kB) | Preview |
Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Service Sector > Institute of Legal Medicine |
UniBE Contributor: |
Weinmann, Wolfgang |
ISSN: |
1618-2642 |
Publisher: |
Springer |
Language: |
English |
Submitter: |
Factscience Import |
Date Deposited: |
04 Oct 2013 14:22 |
Last Modified: |
05 Dec 2022 14:06 |
Publisher DOI: |
10.1007/s00216-010-4598-3 |
PubMed ID: |
21369757 |
Web of Science ID: |
000290912700038 |
BORIS DOI: |
10.7892/boris.7444 |
URI: |
https://boris.unibe.ch/id/eprint/7444 (FactScience: 212706) |