Rotter, R; Martin, H; Fuerderer, S; Gabl, M; Roeder, C; Heini, P; Mittlmeier, T (2010). Vertebral body stenting: a new method for vertebral augmentation versus kyphoplasty. European spine journal, 19(6), pp. 916-23. Berlin: Springer 10.1007/s00586-010-1341-x
|
Text
Rotter2010_Article_VertebralBodyStentingANewMetho.pdf - Published Version Available under License Creative Commons: Attribution-Noncommercial (CC-BY-NC). Download (368kB) | Preview |
Vertebroplasty and kyphoplasty are well-established minimally invasive treatment options for compression fractures of osteoporotic vertebral bodies. Possible procedural disadvantages, however, include incomplete fracture reduction or a significant loss of reduction after balloon tamp deflation, prior to cement injection. A new procedure called "vertebral body stenting" (VBS) was tested in vitro and compared to kyphoplasty. VBS uses a specially designed catheter-mounted stent which can be implanted and expanded inside the vertebral body. As much as 24 fresh frozen human cadaveric vertebral bodies (T11-L5) were utilized. After creating typical compression fractures, the vertebral bodies were reduced by kyphoplasty (n = 12) or by VBS (n = 12) and then stabilized with PMMA bone cement. Each step of the procedure was performed under fluoroscopic control and analysed quantitatively. Finally, static and dynamic biomechanical tests were performed. A complete initial reduction of the fractured vertebral body height was achieved by both systems. There was a significant loss of reduction after balloon deflation in kyphoplasty compared to VBS, and a significant total height gain by VBS (mean +/- SD in %, p < 0.05, demonstrated by: anterior height loss after deflation in relation to preoperative height [kyphoplasty: 11.7 +/- 6.2; VBS: 3.7 +/- 3.8], and total anterior height gain [kyphoplasty: 8.0 +/- 9.4; VBS: 13.3 +/- 7.6]). Biomechanical tests showed no significant stiffness and failure load differences between systems. VBS is an innovative technique which allows for the possibly complete reduction of vertebral compression fractures and helps maintain the restored height by means of a stent. The height loss after balloon deflation is significantly decreased by using VBS compared to kyphoplasty, thus offering a new promising option for vertebral augmentation.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Orthopaedic, Plastic and Hand Surgery (DOPH) > Clinic of Orthopaedic Surgery |
UniBE Contributor: |
Röder, Christoph, Heini, Paul Ferdinand |
ISSN: |
0940-6719 |
Publisher: |
Springer |
Language: |
English |
Submitter: |
Factscience Import |
Date Deposited: |
04 Oct 2013 14:09 |
Last Modified: |
05 Dec 2022 14:00 |
Publisher DOI: |
10.1007/s00586-010-1341-x |
PubMed ID: |
20191393 |
Web of Science ID: |
000278900400007 |
BORIS DOI: |
10.48350/772 |
URI: |
https://boris.unibe.ch/id/eprint/772 (FactScience: 200698) |