PURPOSE

To assess whether iris-claw intraocular lenses (IOLs) undergo gravitation-dependent changes in position and refraction.

SETTING

Tertiary referral center, Bern, Switzerland.

DESIGN

Observational case study.

METHODS

Patients with a history of pars plana vitrectomy and IOL exchange with implantation of an aphakic iris-claw IOL (Artisan) were included in this study. Objective refraction was obtained with a handheld autorefractometer, and the IOL position was measured by ultrasound biomicroscopy with the patient prone, sitting, and supine.

RESULTS

Twenty-one eyes of 19 patients with retropupilary IOLs (13) or prepupillary IOLs (8) were included. The mean spherical equivalent (SE) in the sitting position was -0.81 diopter (D) ± 0.95 (SD), and the mean distance from the endothelium to the anterior edge of the IOL was 3.35 ± 0.72 mm. The mean SE in the supine position was -0.61 ± 1.28 D, whereas the mean SE in the prone position was -1.34 ± 1.17 D (P = .0030). The IOL position changed from 3.50 mm in the supine position to 3.06 mm in the prone position (P < .0001).

CONCLUSIONS

The aphakic iris-claw IOL was subject to significant movement related to gravity. The change in the refractive effect suggests that there is a degree of pseudoaccommodation caused by the forward shift of the aphakic IOL in the face-down position.

FINANCIAL DISCLOSURE

None of the authors has a financial or proprietary interest in any material or method mentioned.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Ophthalmology

UniBE Contributor:

Miller, Mathias, Ebneter, Andreas, Zinkernagel, Martin Sebastian

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0886-3350

Publisher:

Elsevier

Language:

English

Submitter:

Andreas Ebneter

Date Deposited:

09 Jan 2017 15:10

Last Modified:

02 Mar 2023 23:28

Publisher DOI:

10.1016/j.jcrs.2016.07.033

PubMed ID:

27839600

BORIS DOI:

10.7892/boris.91040

URI:

https://boris.unibe.ch/id/eprint/91040

Actions (login required)

Edit item Edit item
Provide Feedback