Reliability Criteria for Liver Stiffness Measurements with Real-Time 2D Shear Wave Elastography in Different Clinical Scenarios of Chronic Liver Disease.

Thiele, M; Madsen, B S; Procopet, B; Hansen, J F; Møller, L M S; Detlefsen, S; Berzigotti, Annalisa; Krag, A (2017). Reliability Criteria for Liver Stiffness Measurements with Real-Time 2D Shear Wave Elastography in Different Clinical Scenarios of Chronic Liver Disease. Ultraschall in der Medizin, 38(6), pp. 648-654. Thieme 10.1055/s-0042-108431

[img] Text
Reliability Criteria for Liver Stiffness Measurements with.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (151kB) | Request a copy

Purpose: Liver stiffness measurement by real-time 2-dimensional shear wave elastography (2D-SWE) lacks universal reliability criteria. We sought to assess whether previously published 2D-SWE reliability criteria for portal hypertension were applicable for the evaluation of liver fibrosis and cirrhosis, and to look for criteria that minimize the risk of misclassification in this setting. Materials and Methods: In a biopsy-controlled diagnostic study, we obtained five 2D-SWE measurements of optimal image quality. Correctly classified cases of fibrosis and cirrhosis were compared to misclassified cases. We compared reliability predictors (standard deviation (SD), SD/mean, size of region of interest (ROI) and difference between a single measurement and the patient's median) with those obtained in a prior study on clinically significant portal hypertension. Results: We obtained 678 2D-SWE measurements from 142 patients. Overall, the variability in liver stiffness within single 2D-SWE measurements was low (SD = 1.1 ± 1.5kPa; SD/mean = 12 ± 9 %). Intra-observer analysis showed almost perfect concordance (intraclass correlation coefficient = 0.95; 95 % CI 0.94 - 0.96; average difference from median = 0.4 ± 0.9kPa). For the diagnosis of cirrhosis, a smaller SD (optimally ≤ 1.75 kPa) and larger ROI size (optimally ≥ 18 mm) were associated with higher accuracy. Similarly, within the published cohort of patients assessed for portal hypertension, a low variability of measurements was associated with high reliability. Conclusion: A high quality 2D-SWE elastogram ensures low variability and high reliability, regardless of indication. We recommend aiming for a combination of low standard deviation and large ROI.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Hepatologie
04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Hepatologie

04 Faculty of Medicine > Department of Gastro-intestinal, Liver and Lung Disorders (DMLL) > Clinic of Visceral Surgery and Medicine > Hepatology
04 Faculty of Medicine > Department of Gastro-intestinal, Liver and Lung Disorders (DMLL) > Clinic of Visceral Surgery and Medicine

UniBE Contributor:

Berzigotti, Annalisa

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0172-4614

Publisher:

Thieme

Language:

English

Submitter:

Lilian Karin Smith-Wirth

Date Deposited:

20 Mar 2017 14:28

Last Modified:

05 Dec 2022 15:01

Publisher DOI:

10.1055/s-0042-108431

Related URLs:

PubMed ID:

27273177

BORIS DOI:

10.7892/boris.93585

URI:

https://boris.unibe.ch/id/eprint/93585

Actions (login required)

Edit item Edit item
Provide Feedback