Malyapa, Robert; Lowe, Matthew; Bolsi, Alessandra; Lomax, Antony J; Weber, Damien Charles; Albertini, Francesca (2016). Evaluation of Robustness to Setup and Range Uncertainties for Head and Neck Patients Treated With Pencil Beam Scanning Proton Therapy. International journal of radiation oncology, biology, physics, 95(1), pp. 154-162. Elsevier 10.1016/j.ijrobp.2016.02.016

[img] Text
1-s2.0-S0360301616001322-main.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (2MB)

PURPOSE

To evaluate the robustness of head and neck plans for treatment with intensity modulated proton therapy to range and setup errors, and to establish robustness parameters for the planning of future head and neck treatments.

METHODS AND MATERIALS

Ten patients previously treated were evaluated in terms of robustness to range and setup errors. Error bar dose distributions were generated for each plan, from which several metrics were extracted and used to define a robustness database of acceptable parameters over all analyzed plans. The patients were treated in sequentially delivered series, and plans were evaluated for both the first series and for the combined error over the whole treatment. To demonstrate the application of such a database in the head and neck, for 1 patient, an alternative treatment plan was generated using a simultaneous integrated boost (SIB) approach and plans of differing numbers of fields.

RESULTS

The robustness database for the treatment of head and neck patients is presented. In an example case, comparison of single and multiple field plans against the database show clear improvements in robustness by using multiple fields. A comparison of sequentially delivered series and an SIB approach for this patient show both to be of comparable robustness, although the SIB approach shows a slightly greater sensitivity to uncertainties.

CONCLUSIONS

A robustness database was created for the treatment of head and neck patients with intensity modulated proton therapy based on previous clinical experience. This will allow the identification of future plans that may benefit from alternative planning approaches to improve robustness.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Radiation Oncology

UniBE Contributor:

Weber, Damien Charles

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0360-3016

Publisher:

Elsevier

Language:

English

Submitter:

Beatrice Scheidegger

Date Deposited:

26 Apr 2017 15:59

Last Modified:

05 Dec 2022 15:02

Publisher DOI:

10.1016/j.ijrobp.2016.02.016

PubMed ID:

27084638

BORIS DOI:

10.7892/boris.94283

URI:

https://boris.unibe.ch/id/eprint/94283

Actions (login required)

Edit item Edit item
Provide Feedback