Sentinel Node Mapping in Cervical and Endometrial Cancer: Indocyanine Green Versus Other Conventional Dyes-A Meta-Analysis.

Ruscito, Ilary; Gasparri, Maria Luisa; Braicu, Elena Ioana; Bellati, Filippo; Raio, Luigi; Sehouli, Jalid; Mueller, Michael; Panici, Pierluigi Benedetti; Papadia, Andrea (2016). Sentinel Node Mapping in Cervical and Endometrial Cancer: Indocyanine Green Versus Other Conventional Dyes-A Meta-Analysis. Annals of surgical oncology, 23(11), pp. 3749-3756. Springer 10.1245/s10434-016-5236-x

[img]
Preview
Text
27160526_art%3A10.1245%2Fs10434-016-5236-x.pdf - Published Version
Available under License Publisher holds Copyright.

Download (589kB) | Preview

BACKGROUND

Historically, blue dyes, (99)Tc or a combination of the two tracers have been used for sentinel lymph node (SLN) mapping in cervical and endometrial cancer patients. Indocyanine green (ICG), as a tracer, has been recently introduced in this setting. Our goal was to assess the differences in overall and bilateral detection rates as well as in false-negative rates among the different tracers.

METHODS

The electronic databases PubMed, MEDLINE, and Scopus were searched in January 2016 by searching the terms "sentinel lymph node" and "dye" and "indocyanine green," and "cervical cancer" or "endometrial cancer." Series comparing different tracers injected intracervically and reporting the detection rate and/or SLN false-negative rate were selected.

RESULTS

Forty-five studies were retrieved. Six studies including 538 patients met selection criteria. Compared with blue dyes, ICG SLN mapping had higher overall (odds ratio [OR] 0.27; 95 % confidence interval [CI] 0.15-0.50; p < 0.0001) and bilateral detection rates (OR 0.27; 95 % CI 0.19-0.40; p < 0.00001). No differences were found between ICG and (99)TC, although these results are based on data of a single series. No differences in overall and bilateral detection rates were found between ICG and the combination of blue dyes and (99)TC. The pooled analysis of false-negative rates data showed no difference in false-negative rates between tracers.

CONCLUSIONS

In cervical and endometrial cancer, ICG SLN mapping seems to be equivalent to the combination of blue dyes and (99)TC in terms of overall and bilateral detection rates. Its safety profile and ease of use may favor its employment respect to conventional tracers.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Gynaecology, Paediatrics and Endocrinology (DFKE) > Clinic of Gynaecology

UniBE Contributor:

Raio, Luigi, Mueller, Michael, Papadia, Andrea

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1068-9265

Publisher:

Springer

Language:

English

Submitter:

Monika Zehr

Date Deposited:

10 May 2017 09:20

Last Modified:

05 Dec 2022 15:02

Publisher DOI:

10.1245/s10434-016-5236-x

PubMed ID:

27160526

BORIS DOI:

10.7892/boris.94519

URI:

https://boris.unibe.ch/id/eprint/94519

Actions (login required)

Edit item Edit item
Provide Feedback