Physical exercise and quantitative lower limb collateral function.

Stoller, Michael; Stoller, David; Seiler, Christian (2016). Physical exercise and quantitative lower limb collateral function. Open Heart, 3(1), e000355. B M J Group 10.1136/openhrt-2015-000355

[img]
Preview
Text
e000355.full.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial (CC-BY-NC).

Download (1MB) | Preview

OBJECTIVE

This study tested the hypothesis that global physical activity and physical performance parameters are directly related to invasively obtained left superficial femoral artery (SFA) collateral flow index (CFI).

BACKGROUND

So far, the association between different measures of physical exercise activity and quantitative lower limb collateral function has not been investigated.

METHODS

The primary study end point was pressure-derived CFI as obtained during a 3 min left SFA balloon occlusion. CFI is the ratio of simultaneously recorded mean SFA distal occlusive pressure divided by mean aortic pressure, both subtracted by central venous pressure. As independent variables, the items of the Global Physical Activity Questionnaire (GPAQ) and physical exercise performance (maximal workload in watts) as achieved during a bicycle or treadmill exercise test were determined. The secondary study end point was transcutaneous left calf partial oxygen pressure (PO2 in mm Hg) divided by transcutaneous PO2 at a non-ischaemic reference site as obtained simultaneously to CFI measurement.

RESULTS

Of the 110 study patients undergoing diagnostic coronary angiography, 79 belonged to the group without and 31 with engagement in regular intensive leisure time physical activity according to GPAQ. Left SFA CFI tended to be lower in the group without than with intensive leisure time physical activity: 0.514 ±0.141 vs 0.560 ±0.184 (p =0.0566). Transcutaneous PO2 index was associated with simultaneous left SFA CFI: CFI =018 +0.57 PO2 index; p<0.0001. Maximal physical workload was directly associated with left SFA CFI: CFI =0.40 +0.0009 maximal workload; p =0.0044.

CONCLUSIONS

Quantitative left SFA collateral function is directly reflected by maximal physical workload as achieved during an exercise test.

TRIAL REGISTRATION NUMBER

NCTO02063347.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology
04 Faculty of Medicine > Department of General Internal Medicine (DAIM) > Clinic of General Internal Medicine

UniBE Contributor:

Stoller, Michael

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2053-3624

Publisher:

B M J Group

Language:

English

Submitter:

Jacques Donzé

Date Deposited:

10 May 2017 14:20

Last Modified:

05 Dec 2022 15:02

Publisher DOI:

10.1136/openhrt-2015-000355

PubMed ID:

26977310

Uncontrolled Keywords:

Collateral circulation; Coronary circulation; Peripheral circulation; Physical exercise; Superficial femoral artery

BORIS DOI:

10.7892/boris.94678

URI:

https://boris.unibe.ch/id/eprint/94678

Actions (login required)

Edit item Edit item
Provide Feedback