Manser, P.

Up a level
Export as [feed] RSS
Group by: Item Type | No Grouping
Number of items: 17.

Mackeprang, P.; Bertholet, J.; Mueller, S.; Guyer, G.; Loebner, H. A.; Frei, D.; Volken, W.; Eliçin, O.; Aebersold, D. M.; Fix, M. K.; Manser, P. (2022). MO-0544 4pi-IMRT based path-finding for dynamic trajectory radiotherapy. Radiotherapy and oncology, 170, S469-S470. Elsevier 10.1016/S0167-8140(22)02378-7

Bertholet, J.; Mackeprang, P.; Loebner, H.L.; Mueller, S.; Guyer, G.; Wyss, Y.; Frei, D.; Volken, W.; Eliçin, O.; Aebersold, D. M.; Fix, M. K.; Manser, P. (2022). PO-1683 Mechanical and dosimetric accuracy of Dynamic Trajectory Radiotherapy delivery on a C-arm linac. Radiotherapy and oncology, 170, S1482-S1483. Elsevier 10.1016/S0167-8140(22)03647-7

Fix, M. K.; Mueller, S.; Volken, W.; Terribilini, D.; Frei, D.; Eliçin, O.; Aebersold, D. M.; Manser, P. (24 October 2020). Dosimetric Comparison of Dynamic Trajectory Radiotherapy, HyperArc and VMAT Treatment Plans. International journal of radiation oncology, biology, physics, 108(3S), e295-e295. Elsevier 10.1016/j.ijrobp.2020.07.705

Fix, M. K.; Mueller, S.; Volken, W.; Terribilini, D.; Frei, D.; Eliçin, O.; Aebersold, D. M.; Manser, P. (24 October 2020). Comparison of Treatment Plan Robustness Between Dynamic Trajectory Radiotherapy and VMAT. International Journal of Radiation Oncology*Biology*Physics, 108(3), e330-e331. 10.1016/j.ijrobp.2020.07.789

Manser, P.; Mueller, S.; Guyer, G.; Koechli, C.; Volken, W.; Bertholet, J.; Aebersold, D. M.; Fix, M. K. (24 October 2020). Advanced Dynamic Trajectory Radiotherapy Using Table Translations and Rotations. International journal of radiation oncology, biology, physics, 108(3), e335. Elsevier 10.1016/j.ijrobp.2020.07.801

Kueng, R.; Oborn, B. M.; Roberts, N. F.; Causer, T.; Stampanoni, M. F. M.; Manser, P.; Keall, P. J.; Fix, M. K. (2020). Towards MR-guided electron therapy: Measurement and simulation of clinical electron beams in magnetic fields. Physica medica, 78, pp. 83-92. Elsevier 10.1016/j.ejmp.2020.09.001

Küng, R.; Guyer, G.; Volken, W.; Frei, D.; Stabel, F.; Stampanoni, P.; Manser, P.; Fix, M. (11 July 2020). Enabling Fast and Accurate Dose Calculation in Magnetic Fields Using Macro Monte Carlo (Unpublished). In: AAPM Annual Meeting.

Küng, R.; Löbner, H.; Müller, S.; Frei, D.; Volken, W.; Aebersold, D.; Stampanoni, M.F.M.; Fix, M.; Manser, P. (11 July 2020). Monte Carlo Based Treatment Plan Optimization for Intensity Modulated Proton Therapy (Unpublished). In: AAPM Annual Meeting.

Küng, R.; Müller, S.; Löbner, H.; Frei, D.; Volken, W.; Aebersold, D.; Stampanon, M.F.M.; Fix, M.; Manser, P. (11 July 2020). Development of a Simultaneous Optimization Process for Photon, Electron and Proton Beams (TriB-RT (Unpublished). In: AAPM Annual Meeting.

Tessarini, S.; Fix, M.; Volken, W.; Frei, D.; Manser, P. (11 July 2020). Monte Carlo Simulation of Laboratory X-Ray Grating Interferometry Setups (Unpublished). In: AAPM Annual Meeting.

Löbner, H.; Frei, D.; Volken, W.; Müller, S.; Aebersold, D.; Stampanoni, M.F.M.; Manser, P. (11 July 2020). Development of a Framework for Monte Carlo Dose Calculation of Intensity Modulated Proton Plans (Unpublished). In: AAPM Annual Meeting.

Müller, S.; Schoch, A.; Torelli, N.; Duetschler, A.; Fix, M.; Henzen, D.; Joosten, A.; Aebersold, D.; Stampanoni, M.F.M.; Manser, P. (11 July 2020). Enhancing Efficiency of a Treatment Planning Process for Mixed Beam Radiotherapy Towards Clinical Usability (Unpublished). In: AAPM Annual Meeting.

Müller, S.; Torelli, N; Duetschler, A.; Eliçin, O.; Aebersold, D.; Stampanoni, M.F.M.; Fix, M.; Manser, P. (11 July 2020). Hybrid Direct Aperture Optimization for VMAT, Dynamic Trajectory Radiotherapy (DTRT) and Dynamic Mixed Beam Radiotherapy (DYMBER) (Unpublished). In: AAPM Annual Meeting.

Heath, E.; Müller, S.; Guyer, G.; Duetschler, A.; Fix, M.; Manser, P. (2020). Experimental Validation of Delivery of Robust Mixed-Beam Radiotherapy Plans (Unpublished). In: AAPM Annual Meeting.

Kiss, M.; Zhang, H.; Fix, M.K.; Manser, P.; Xing, L. (2020). Z-Super Resolution CT-Image Generation With A Deep 3D Fully Convolutional Neural Network. International journal of radiation oncology, biology, physics, 108(3, Suppl 1), e784-e784. Elsevier 10.1016/j.ijrobp.2020.07.249

Mueller, S; Manser, P.; Volken, W.; Frei, D.; Kueng, R; Herrmann, E.; Eliçin, O.; Aebersold, D. M.; Stampanoni, M F M; Fix, M. K. (2018). Part 2: Dynamic mixed beam radiotherapy (DYMBER): Photon dynamic trajectories combined with modulated electron beams. Medical physics, 45(9), pp. 4213-4226. American Association of Physicists in Medicine AAPM 10.1002/mp.13085

Schmidhalter, D.; Fix, M.; Wyss, M.; Schaer, N.; Munro, P.; Scheib, S.; Kunz, P.; Manser, P. (2013). Evaluation of a new six degrees of freedom couch for radiation therapy. Medical physics, 40(11), p. 111710. American Association of Physicists in Medicine AAPM 10.1118/1.4823789

This list was generated on Thu Nov 21 14:29:55 2024 CET.
Provide Feedback