Mitigating the negative impacts of tall wind turbines on bats: Vertical activity profiles and relationships to wind speed

Wellig, Sascha; Nusslé, Sébastien; Miltner, Daniela Caroline; Kohle, Oliver; Glaizot, Olivier; Braunisch, Veronika; Obrist, Martin K.; Arlettaz, Raphaël (2018). Mitigating the negative impacts of tall wind turbines on bats: Vertical activity profiles and relationships to wind speed. PLoS ONE, 13(3), e0192493. Public Library of Science 10.1371/journal.pone.0192493

[img]
Preview
Text
Wellig_PLOSONE2018.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

Wind turbines represent a source of hazard for bats, especially through collision with rotor blades. With increasing technical development, tall turbines (rotor-swept zone 50–150 m above ground level) are becoming widespread, yet we lack quantitative information about species active at these heights, which impedes proposing targeted mitigation recommenda- tions for bat-friendly turbine operation. We investigated vertical activity profiles of a bat assemblage, and their relationships to wind speed, within a major valley of the European Alps where tall wind turbines are being deployed. To monitor bat activity we installed auto- matic recorders at sequentially increasing heights from ground level up to 65 m, with the goal to determine species-specific vertical activity profiles and to link them to wind speed. Bat call sequences were analysed with an automatic algorithm, paying particular attention to mouse-eared bats (Myotis myotis and Myotis blythii) and the European free-tailed bat (Tadarida teniotis), three locally rare species. The most often recorded bats were the Com- mon pipistrelle (Pipistrellus pipistrellus) and Savi’s pipistrelle (Hypsugo savii). Mouse-eared bats were rarely recorded, and mostly just above ground, appearing out of risk of collision. T. teniotis had a more evenly distributed vertical activity profile, often being active at rotor level, but its activity at that height ceased above 5 ms-1 wind speed. Overall bat activity in the rotor-swept zone declined with increasing wind speed, dropping below 5% above 5.4 ms-1. Collision risk could be drastically reduced if nocturnal operation of tall wind turbines would be restricted to wind speeds above 5 ms-1. Such measure should be implemented year-round because T. teniotis remains active in winter. This operational restriction is likely to cause only small energy production losses at these tall wind turbines, although further analyses are needed to assess these losses precisely.

Item Type:

Journal Article (Original Article)

Division/Institute:

08 Faculty of Science > Department of Biology > Institute of Ecology and Evolution (IEE) > Conservation Biology
08 Faculty of Science > Department of Biology > Institute of Ecology and Evolution (IEE)

UniBE Contributor:

Wellig, Sascha, Nusslé, Sébastien, Miltner, Daniela Caroline, Braunisch, Veronika, Arlettaz, Raphaël

Subjects:

500 Science > 570 Life sciences; biology
500 Science > 590 Animals (Zoology)

ISSN:

1932-6203

Publisher:

Public Library of Science

Language:

English

Submitter:

Olivier Roth

Date Deposited:

12 Mar 2019 14:45

Last Modified:

05 Dec 2022 15:26

Publisher DOI:

10.1371/journal.pone.0192493

PubMed ID:

29561851

BORIS DOI:

10.7892/boris.126999

URI:

https://boris.unibe.ch/id/eprint/126999

Actions (login required)

Edit item Edit item
Provide Feedback