Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations.

Schimmel, Martin; Walther, Moritz; Al-Haj Husain, Nadin; Igarashi, Kensuke; Wittneben, Julia; Abou-Ayash, Samir (2021). Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations. Clinical oral investigations, 25(11), pp. 6297-6307. Springer 10.1007/s00784-021-03928-2

[img]
Preview
Text
Schimmel2021_Article_RetentionForcesBetweenPrimaryA.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

OBJECTIVES

To analyze the retention forces between primary and secondary telescopic crowns milled from various materials and to compare them with the retention forces between cast telescopic crowns made of precious metal alloys.

MATERIALS AND METHODS

Primary and secondary crowns (N = 60; n = 10 per group) were fabricated using various material combinations (1: zirconia [ZIR]/polyether ether ketone [PEEK]; 2: titanium grade IV [TI]/PEEK; 3: PEEK/PEEK; 4: non-precious alloy [NPA]/PEEK; 5:NPA/NPA), while precious alloy (PA) was used for the control group (6: PA/PA). The retention forces at 10, 1000, 5000, and 10,000 connection and disconnection cycles and the relative weights were analyzed, applying nonparametric repeated measures ANOVA and post hoc Mann-Whitney and Wilcoxon signed-rank tests (α < 0.05).

RESULTS

Globally, significant differences in the retention forces among the materials (p < 0.0001), time points (p < 0.0001), and wear resistance for the various materials (p < 0.0001) were observed. No significant changes in retention forces compared to baseline were observed in groups 2, 4, 5, and 6. A significantly higher weight loss for both primary and secondary crowns was observed in groups 4 and 6.

CONCLUSIONS

The material combination in telescopic attachments influences retention forces and wear. Interactions between materials and time were evident, indicating that the change in retention forces differs among the materials. The combinations of milled TI/PEEK and NPA/NPA qualify for further preclinical testing in a more clinically realistic setup, determining a material-specific double-crown design.

CLINICAL RELEVANCE

The design of precious alloy telescopic crowns cannot be directly transferred to other milled material combinations due to different retention behaviors.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology

UniBE Contributor:

Schimmel, Martin, Al-Haj Husain, Nadin, Wittneben, Julia, Abou-Ayash, Samir

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1436-3771

Publisher:

Springer

Language:

English

Submitter:

Tina Lauper

Date Deposited:

16 Jun 2021 18:01

Last Modified:

05 Dec 2022 15:51

Publisher DOI:

10.1007/s00784-021-03928-2

PubMed ID:

33834311

Uncontrolled Keywords:

Alloy PEEK Retention force Telescopic crown Wear Zirconia

BORIS DOI:

10.48350/156452

URI:

https://boris.unibe.ch/id/eprint/156452

Actions (login required)

Edit item Edit item
Provide Feedback