A Double-Blind Crossover RCT Analyzing Technical and Clinical Performance of Monolithic ZrO2 Implant Fixed Dental Prostheses (iFDP) in Three Different Digital Workflows

Gintaute, Aiste; Weber, Karin; Zitzmann, Nicola U.; Brägger, Urs; Ferrari, Marco; Joda, Tim (2021). A Double-Blind Crossover RCT Analyzing Technical and Clinical Performance of Monolithic ZrO2 Implant Fixed Dental Prostheses (iFDP) in Three Different Digital Workflows. Journal of clinical medicine, 10(12), p. 2661. MDPI 10.3390/jcm10122661

[img]
Preview
Text
jcm-10-02661.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

This double-blind randomized controlled trial with a crossover design analyzed the technical and clinical performance of three-unit monolithic ZrO2 implant-fixed dental prostheses (iFDPs), prepared using two complete digital workflows (Test-1, Test-2) and one mixed analog–digital workflow (Control). Each of the 20 study patients received three iFDPs, resulting in 60 restorations for analysis. The quality of the restorations was assessed by analyzing laboratory cross-mounting and calculating the chairside adjustment time required during fitting. All iFDPs could be produced successfully with all three workflows. The highest cross-mounting success rate was observed for the original pairing iFDP/model of the Control group. Overall, 60% of iFDPs prepared with Test-1 workflow did not require chairside adjustment compared with 50% for Test-2 and 30% for Controls. The mean total chairside adjustment time, as the sum of interproximal, pontic, and occlusal corrections was 2.59 ± 2.51 min (Control), 2.88 ± 2.86 min (Test-1), and 3.87 ± 3.02 min (Test-2). All tested workflows were feasible for treatment with iFDPs in posterior sites on a soft tissue level type implant system. For clinical routine, it has to be considered that chairside adjustments may be necessary, at least in every second patient, independent on the workflow used.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology

UniBE Contributor:

Brägger, Urs

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2077-0383

Publisher:

MDPI

Language:

English

Submitter:

Tina Lauper

Date Deposited:

28 Jun 2021 11:28

Last Modified:

05 Dec 2022 15:51

Publisher DOI:

10.3390/jcm10122661

BORIS DOI:

10.48350/156962

URI:

https://boris.unibe.ch/id/eprint/156962

Actions (login required)

Edit item Edit item
Provide Feedback