Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study

Mariani, Christopher; Zlotnick, Joshua; Harrysson, Ola; Marcellin-Little, Denis; Malinak, Kristen; Gavitt, Ashley; Guevar, Julien (2021). Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: A cadaveric study. Veterinary surgery, 50(2), pp. 294-302. Wiley-Blackwell 10.1111/vsu.13557

[img] Text
Veterinary Surgery - 2021 - Mariani - Accuracy of three%u2010dimensionally printed animal%u2010specific drill guides for implant.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

Objective: To assess the accuracy of three-dimensionally (3-D) printed drill guides in constraining the trajectory of drill tracts for implants in canine thoracic vertebrae.

Study design: Experimental ex vivo study.

Sample population: Five canine thoracic vertebral column specimens.

Methods: Guides to constrain drill trajectories were designed on the basis of computed tomographic (CT) imaging of six thoracic vertebrae (T8-T13) and were 3-D printed. The guides were used to create drill tracts in these vertebrae by both an experienced and a novice surgeon, and CT imaging was repeated. The entry point and angulation of actual and planned drill tracts were compared for both surgeons. Unintended cortical violations were also assessed by using a modified Zdichavsky classification.

Results: Fifty-eight drill tracts were created in 30 vertebrae. Mean entry point deviation was 1.4 mm (range, 0.4-3.4), and mean angular deviation was 5.1° (range, 1.5°-10.8°). There were no differences between surgeons in entry point deviation (P = .07) or angular deviation (P = .22). There were no unintended cortical bone violations, and all drill tracts were classified as modified Zdichavsky grade I.

Conclusion: The 3-D printed guides used in the current study yielded drill tracts with small linear and angular errors from intended paths and 100% accuracy for placement within vertebral pedicles and bodies. This technique was conveniently used by both an experienced and a novice surgeon.

Clinical significance: This technique might be immediately applicable to clinical cases requiring thoracic vertebral stabilization and may allow safe and accurate implant placement for surgeons with varying experience levels.

Item Type:

Journal Article (Original Article)

Division/Institute:

05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > DKV - Clinical Neurology
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > Small Animal Clinic > Small Animal Clinic, Surgery
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > Small Animal Clinic

UniBE Contributor:

Guevar, Julien Jean

Subjects:

500 Science > 570 Life sciences; biology
500 Science > 590 Animals (Zoology)
600 Technology > 610 Medicine & health

ISSN:

0161-3499

Publisher:

Wiley-Blackwell

Language:

English

Submitter:

Manuel Roland Schmidli

Date Deposited:

10 Feb 2022 15:15

Last Modified:

05 Dec 2022 16:05

Publisher DOI:

10.1111/vsu.13557

PubMed ID:

33373470

BORIS DOI:

10.48350/164747

URI:

https://boris.unibe.ch/id/eprint/164747

Actions (login required)

Edit item Edit item
Provide Feedback