Bardhi, Anisa; Zaghini, Anna; Levionnois, Olivier; Barbarossa, Andrea (2021). A quick approach for medetomidine enantiomer determination in dog plasma by chiral liquid chromatography–tandem mass spectrometry and application to a pharmacokinetic study. Drug testing and analysis, 13(7), pp. 1249-1255. Wiley 10.1002/dta.3015
Text
Drug_Testing_and_Analysis_-_2021_-_Bardhi_-_A_quick_approach_for_medetomidine_enantiomer_determination_in_dog_plasma_by.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (1MB) |
In the present study, a rapid, sensitive and high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of medetomidine enantiomers in dog plasma was developed and validated. The separation and individual quantification of chiral compounds can be a tricky task in LC. This is particularly true when target analytes have a relatively small mass, as is the case with medetomidine, a potent and highly specific α2-adrenoceptor agonist widely used in both human and veterinary medicine. The proposed approach is based on a quick liquid-liquid extraction with ethyl acetate and filtration prior to injection. The optimized mobile phase composition allowed to perfectly separate the two enantiomers of medetomidine in a short chromatographic run time, using a cellulose tris(4-methylbenzoate)-based chiral column. A lower limit of quantification of 0.1 ng/mL was reached for both analytes thanks to the high sensitivity and selectivity of MS/MS and the use of racemic medetomidine-d3 as internal standard prevented potential matrix effect. Linearity was satisfying (R2 > 0.99) over the range 0.1-25 ng/mL, as well as within- and between-session accuracy and precision, both always <15%. This method was also applied with success to a series of samples from a pharmacokinetic (PK) study aimed at comparing dex- and levomedetomidine behaviour after administration of the racemic mixture in dogs. The simple extraction procedure, which allows reduced solvent and time consumption without compromising analytical performances, makes this technique a useful tool for this kind of applications even when small animals are involved, due to the small amount of sample required.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > DKV - Anaesthesiology 05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) |
UniBE Contributor: |
Levionnois, Olivier |
Subjects: |
600 Technology > 630 Agriculture |
ISSN: |
1942-7603 |
Publisher: |
Wiley |
Language: |
English |
Submitter: |
Claudia Spadavecchia |
Date Deposited: |
16 Feb 2022 16:05 |
Last Modified: |
17 Apr 2024 16:04 |
Publisher DOI: |
10.1002/dta.3015 |
PubMed ID: |
33569906 |
BORIS DOI: |
10.48350/165011 |
URI: |
https://boris.unibe.ch/id/eprint/165011 |