Verhoog, Sanne; Gubelmann, Cédric; Bano, Arjola; Muka, Taulant; Franco, Oscar H; Marques-Vidal, Pedro (2023). Comparison of different software for processing physical activity measurements with accelerometry. Scientific Reports, 13(1), p. 2879. Nature Publishing Group 10.1038/s41598-023-29872-7
|
Text
s41598-023-29872-7.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (1MB) | Preview |
Several raw-data processing software for accelerometer-measured physical activity (PA) exist, but whether results agree has not been assessed. We examined the agreement between three different software for raw accelerometer data, and associated their results with cardiovascular risk. A cross-sectional analysis conducted between 2014 and 2017 in 2693 adults (53.4% female, 45-86 years) living in Lausanne, Switzerland was used. Participants wore the wrist-worn GENEActive accelerometer for 14 days. Data was processed with the GENEActiv manufacturer software, the Pampro package in Python and the GGIR package in R. For the latter, two sets of thresholds "White" and "MRC" defining levels of PA and two versions (1.5-9 and 1.11-1) for the "MRC" threshold were used. Cardiovascular risk was assessed using the SCORE risk score. Time spent (mins/day) in stationary, light, moderate and vigorous PA ranged from 633 (GGIR-MRC) to 1147 (Pampro); 93 (GGIR-White) to 196 (GGIR-MRC); 19 (GGIR-White) to 161 (GENEActiv) and 1 (GENEActiv) to 26 (Pampro), respectively. Spearman correlations between results ranged between 0.317 and 0.995, while concordance coefficients ranged between 0.035 and 0.968. With some exceptions, the line of perfect agreement was not in the 95% confidence interval of the Bland-Altman plots. Compliance to PA guidelines varied considerably: 99.8%, 98.7%, 76.3%, 72.6% and 50.2% for Pampro, GENEActiv, GGIR-MRC v.1.11-1, GGIR-MRC v.1.4-9 and GGIR-White, respectively. Cardiovascular risk decreased with increasing time spent in PA across most software packages. We found large differences in PA estimation between software and thresholds used, which makes comparability between studies challenging.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM) 04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology |
UniBE Contributor: |
Verhoog, Sanne, Bano, Arjola, Muka, Taulant, Franco Duran, Oscar Horacio |
Subjects: |
600 Technology > 610 Medicine & health 300 Social sciences, sociology & anthropology > 360 Social problems & social services |
ISSN: |
2045-2322 |
Publisher: |
Nature Publishing Group |
Funders: |
[4] Swiss National Science Foundation |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
23 Feb 2023 14:25 |
Last Modified: |
14 Mar 2023 12:41 |
Publisher DOI: |
10.1038/s41598-023-29872-7 |
PubMed ID: |
36806337 |
BORIS DOI: |
10.48350/179056 |
URI: |
https://boris.unibe.ch/id/eprint/179056 |