Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study.

Molinero Mourelle, Pedro; Peter, Lukas; Gaviria, Ana Sol; Fonseca, Manrique; Schimmel, Martin; Katsoulis, Joannis (2023). Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study. Acta odontologica Scandinavica, 81(8), pp. 591-596. Taylor & Francis 10.1080/00016357.2023.2223715

[img] Text
Tactile_misfit_detection_ability_at_the_implant_abutment_interface_of_internal_connection_dental_implants_an_in_vitro_study.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB)

OBJECTIVE

The aim of this in-vitro study was to investigate the tactile assessment ability at the implant impression-taking stage.

METHODS

Thirty clinicians (18 novices, 12 experts) were included for a tactile fit assessment by using a used/new probe (tip diameter 100 µm/20 µm). Six implant replicas and related impression copings of two internal connection implant systems were used, each with a perfect fit (0 µm) and defined vertical micro gaps of 8, 24, 55, 110 and 220 µm at the interface. Statistical analysis was performed using descriptive methods and non-parametric tests with a focus on specificity (ability to detect perfect fit), sensitivity (ability to detect misfit), and predictive values. P-values <5% were considered statistically significant.

RESULTS

The tactile assessment showed a mean total sensitivity for the Straumann and Nobel Biocare systems of 83% and 80% with a used probe, and 91% and 92% with a new probe, respectively. The mean total specificities were 33% and 20% with a used probe and 17% and 3% with a new probe, respectively. No statistical significance was observed between novice and expert clinicians concerning their tactile assessment ability.

CONCLUSIONS

The ability to detect a perfect fit (specificity) with a probe was very poor for both implant systems and impaired with the use of a new probe. The use of a new probe improved the gap detection ability (sensitivity) significantly at the expense of the specificity. A combination of additional chairside techniques with training and calibration could improve clinicians' ability to correctly assess the fit/misfit at the implant-abutment interface.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology
04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology [discontinued]

UniBE Contributor:

Molinero Mourelle, Pedro, Peter, Lukas, Gaviria Vélez, Ana Sol, Fonseca Escalante, Manrique, Schimmel, Martin, Katsoulis, Joannis

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1502-3850

Publisher:

Taylor & Francis

Language:

English

Submitter:

Pubmed Import

Date Deposited:

16 Jun 2023 14:35

Last Modified:

22 Oct 2023 00:12

Publisher DOI:

10.1080/00016357.2023.2223715

PubMed ID:

37319413

Uncontrolled Keywords:

Dental implants dental abutment connection dental implant-abutment design dental impression implant-abutment interface