Effect of triangular mesh resolution on the geometrical trueness of segmented CBCT maxillofacial data into STL format.

Elbashti, Mahmoud; Molinero-Mourelle, Pedro; Aswehlee, Amel; Bornstein, Michael M; Abou-Ayash, Samir; Schimmel, Martin; Ella, Bruno; Naveau, Adrien (2023). Effect of triangular mesh resolution on the geometrical trueness of segmented CBCT maxillofacial data into STL format. Journal of dentistry, 138, p. 104722. Elsevier Science 10.1016/j.jdent.2023.104722

[img]
Preview
Text
s10334-023-01119-6.pdf - Accepted Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (1MB) | Preview

OBJECTIVES

To determine the optimal level of mesh reduction that would maintain acceptable levels of geometrical trueness while also minimizing the impact on other parameters such as file size and processing time.

METHODS AND METHODS

Intraoral and extraoral maxillofacial defects were created on 8 cadaver heads and scanned by using a CBCT scanner (NewTom 3D Imaging, Verona). DICOM data were segmented to produce head (n=8) and skull models (n=8) saved as standard tessellation language (STL) files. A further processing of head models was preformed to produce face (n=8) and ear models (n=8). A mesh reduction process was performed for each STL model (reference, R0) by generating 50% (R1), 75% (R2), and 90% (R3) reductions. The 3 datasets were compared to the R0 file using 3D evaluation software (GOM Inspect) using a global best-fit algorithm, to calculate the root mean square (RMS) deviations. Statistical analyses were performed at a level of significance of α=0.05.

RESULTS

There was no 3D deviation after the 50% triangular mesh reduction in the 4 datasets. Minor 3D deviations were observed after 75% reduction, in all groups. After 90% reduction, higher 3D deviations were observed, and especially in head and skull. Statistically significant increase in 3D deviations was observed with higher degrees of mesh reduction (p < 0.001).

CONCLUSION

The resolution of CBCT-based maxillofacial defect models can be reduced up to 50%, with neglectable concern to inaccuracy.

CLINICAL SIGNIFICANCE

Accurate maxillofacial models can be obtained from CBCT DICOM files after segmentation and export as STL files, even when the mesh resolution is reduced up to 50%. This information can be valuable for practitioners and researchers working with 3D models of maxillofacial defects.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology

UniBE Contributor:

Molinero Mourelle, Pedro, Abou-Ayash, Samir, Schimmel, Martin

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0300-5712

Publisher:

Elsevier Science

Language:

English

Submitter:

Pubmed Import

Date Deposited:

25 Sep 2023 10:55

Last Modified:

23 Sep 2024 00:25

Publisher DOI:

10.1016/j.jdent.2023.104722

PubMed ID:

37742810

Uncontrolled Keywords:

3D deviation CBCT maxillofacial defect resolution trueness

BORIS DOI:

10.48350/186555

URI:

https://boris.unibe.ch/id/eprint/186555

Actions (login required)

Edit item Edit item
Provide Feedback