Paolucci, Iwan; Bulatović, Milica; Weber, Stefan; Tinguely, Pascale (2023). Thermal ablation with configurable shapes: a comprehensive, automated model for bespoke tumor treatment. European radiology experimental, 7(1), p. 67. Springer 10.1186/s41747-023-00381-6
|
Text
s41747-023-00381-6.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (2MB) | Preview |
BACKGROUND
Malignant tumors routinely present with irregular shapes and complex configurations. The lack of customization to individual tumor shapes and standardization of procedures limits the success and application of thermal ablation.
METHODS
We introduced an automated treatment model consisting of (i) trajectory and ablation profile planning, (ii) ablation probe insertion, (iii) dynamic energy delivery (including robotically driven control of the energy source power and location over time, according to a treatment plan bespoke to the tumor shape), and (iv) quantitative ablation margin verification. We used a microwave ablation system and a liver phantom (acrylamide polymer with a thermochromic ink) to mimic coagulation and measure the ablation volume. We estimated the ablation width as a function of power and velocity following a probabilistic model. Four representative shapes of liver tumors < 5 cm were selected from two publicly available databases. The ablated specimens were cut along the ablation probe axis and photographed. The shape of the ablated volume was extracted using a color-based segmentation method.
RESULTS
The uncertainty (standard deviation) of the ablation width increased with increasing power by ± 0.03 mm (95% credible interval [0.02, 0.043]) per watt increase in power and by ± 0.85 mm (95% credible interval [0, 2.5]) per mm/s increase in velocity. Continuous ablation along a straight-line trajectory resulted in elongated rotationally symmetric ablation shapes. Simultaneous regulation of the power and/or translation velocity allowed to modulate the ablation width at specific locations.
CONCLUSIONS
This study offers the proof-of-principle of the dynamic energy delivery system using ablation shapes from clinical cases of malignant liver tumors.
RELEVANCE STATEMENT
The proposed automated treatment model could favor the customization and standardization of thermal ablation for complex tumor shapes.
KEY POINTS
• Current thermal ablation systems are limited to ellipsoidal or spherical shapes. • Dynamic energy delivery produces elongated rotationally symmetric ablation shapes with varying widths. • For complex tumor shapes, multiple customized ablation shapes could be combined.