Inter- and intraindividual variability in virtual single-tooth implant positioning.

Raabe, Clemens; Biel, Philippe; Dulla, Fabrice A; Janner, Simone F M; Abou-Ayash, Samir; Couso-Queiruga, Emilio (2023). Inter- and intraindividual variability in virtual single-tooth implant positioning. (In Press). Clinical oral implants research Wiley 10.1111/clr.14203

[img] Text
Clinical_Oral_Implants_Res_-_2023_-_Raabe_-_Inter__and_intraindividual_variability_in_virtual_single_tooth_implant.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

OBJECTIVES

The purpose of this prospective study was to determine the inter- and intraindividual variability in virtual single-tooth implant positioning based on the level of expertise, specialty, total time spent, and the use of a prosthetic tooth setup.

MATERIALS AND METHODS

Virtual implant planning was performed on matched pre- and post-extraction intraoral scans (IOS), and cone-beam computed tomography scans of 15 patients. Twelve individual examiners, involving six novices and experts from oral surgery and prosthodontics positioned the implants, first based on anatomical landmarks utilizing only the post-extraction, and second with the use of the pre-extraction IOS as a setup. The time for implant positioning was recorded. After 1 month, all virtual plannings were performed again. The individual implant positions were superimposed to obtain 3D deviations using a software algorithm.

RESULTS

An interindividual variability with mean angular, crestal, and apical positional deviations of 3.8 ± 1.94°, 1.11 ± 0.55, and 1.54 ± 0.66 mm, respectively, was found. When assessing intraindividual variability, deviations of 3.28 ± 1.99°, 0.78 ± 0.46, and 1.12 ± 0.61 mm, respectively, were observed. Implants planned by experts exhibited statistically lower deviations compared to those planned by novices. Longer planning times resulted in lower deviations in the experts' group but not in the novices. Oral surgeons demonstrated lower crestal, but not angular and apical deviations than prosthodontists. The use of a setup only led to minor adjustments.

CONCLUSIONS

Substantial inter- and intraindividual variability exists during implant positioning utilizing specialized software planning. The level of expertise and the time invested influenced the deviations of the implant position during the planning sequence.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology
04 Faculty of Medicine > School of Dental Medicine > Department of Oral Surgery and Stomatology
04 Faculty of Medicine > School of Dental Medicine

UniBE Contributor:

Raabe, Clemens, Biel, Philippe Marco, Dulla, Fabrice Alain, Abou-Ayash, Samir, Couso-Queiruga, Emilio

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1600-0501

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

16 Nov 2023 12:12

Last Modified:

17 Nov 2023 05:03

Publisher DOI:

10.1111/clr.14203

PubMed ID:

37966052

Uncontrolled Keywords:

alveolar ridge computer-assisted dental implants digital digital imaging image processing implant planning

BORIS DOI:

10.48350/188956

URI:

https://boris.unibe.ch/id/eprint/188956

Actions (login required)

Edit item Edit item
Provide Feedback