Method-comparison study between a watch-like sensor and a cuff-based device for 24-h ambulatory blood pressure monitoring.

Proença, Martin; Ambühl, Jeremias; Bonnier, Guillaume; Meister, Théo A.; Valentin, Jérémy; Soria, Rodrigo; Ferrario, Damien; Lemay, Mathieu; Rexhaj, Emrush (2023). Method-comparison study between a watch-like sensor and a cuff-based device for 24-h ambulatory blood pressure monitoring. Scientific reports, 13(1), p. 6149. Springer Nature 10.1038/s41598-023-33205-z

[img]
Preview
Text
Method-comparison_study_between_a_watch-like_sensor_and_a_cuff-based_device_for_24-h_ambulatory_blood_pressure_monitoring.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (2MB) | Preview

The use of 24-h ambulatory blood pressure monitoring (ABPM) has been continuously increasing over the last decades. However, cuff-based devices may cause discomfort, particularly at night, leading to potentially non-representative blood pressure (BP) values. We investigated the feasibility of a cuff-less BP monitoring solution in 67 subjects undergoing conventional 24-h ABPM. A watch-like optical sensor was attached at the upper arm or wrist at the contralateral side of the cuff. Systolic (SBP) and diastolic BP (DBP) values were estimated from the measured optical signals by pulse wave analysis. Average 24-h, daytime and nighttime BP values were compared between the conventional monitor and the cuff-less sensor. The differences between both methods-expressed as mean ± standard deviation (95% limits of agreement)-were of - 1.8 ± 6.2 mmHg (- 13.9, 10.3) on SBP and - 2.3 ± 5.4 mmHg (- 13.0, 8.3) on DBP for 24-h averages, of - 1.5 ± 6.6 mmHg (- 14.4, 11.4) on SBP and - 1.8 ± 5.9 mmHg (- 13.4, 9.9) on DBP for daytime averages, and of 0.4 ± 7.5 mmHg (- 14.4, 15.1) on SBP and - 1.3 ± 6.8 mmHg (- 14.7, 12.0) on DBP for nighttime averages. These results encouragingly suggest that cuff-less 24-h ABPM may soon become a clinical possibility.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Meister, Théo Arthur Perceval, Valentin, Jérémy Pierre Patrick, Rexhaj, Emrush

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2045-2322

Publisher:

Springer Nature

Language:

English

Submitter:

Vjollca Coli

Date Deposited:

04 Jan 2024 11:15

Last Modified:

04 Jan 2024 11:16

Publisher DOI:

10.1038/s41598-023-33205-z

PubMed ID:

37061569

BORIS DOI:

10.48350/191181

URI:

https://boris.unibe.ch/id/eprint/191181

Actions (login required)

Edit item Edit item
Provide Feedback