Clinical and radiographic performance of late placed and early loaded dental implants with a conditioned hydrophilic surface in posterior mandible sites: A prospective case series with an 8.5- to 9.5-year follow-up.

Molinero-Mourelle, Pedro; Schimmel, Martin; Forrer, Fiona Alena; Hicklin, Stefan Paul; Raabe, Clemens; Chappuis, Vivianne; Fonseca, Manrique (2024). Clinical and radiographic performance of late placed and early loaded dental implants with a conditioned hydrophilic surface in posterior mandible sites: A prospective case series with an 8.5- to 9.5-year follow-up. (In Press). Clinical implant dentistry and related research Wiley 10.1111/cid.13333

[img]
Preview
Text
Clin_Implant_Dent_Rel_Res_-_2024_-_Molinero_Mourelle_-_Clinical_and_radiographic_performance_of_late_placed_and_early.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (1MB) | Preview

OBJECTIVE

To assess the clinical outcomes by means of implant and prosthetic survival of late placed and early loaded implants with a hydrophilic, moderately rough surface for partially edentulous patients after a follow-up of 8.5 to 9.5 years.

MATERIALS AND METHODS

A prospective case series study involving 15 patients with single, late placed and early loaded implants in the posterior mandible was performed. Clinical and radiographical parameters, including biological and technical complications and patient satisfaction, were assessed.

RESULTS

From an initial sample of 15 patients, 12 were included. A total of 16 implants were observed. After a mean follow-up of 9 years and 7 months (SD ± 3.8 months), implant success and survival rate were 100%. The prosthetic survival rate was 100%, and the prosthetic success rate was 93.8% since a major chipping was observed. No biological complications were observed, and the mean modified plaque index was 0.03 (SD ± 0.09) with a mean probing pocket depth of 2.95 mm (SD ± 0.09). A mean marginal bone level (MBL) of 0.04 mm (SD ± 0.88) and a mean VAS of 9.42 (SD ± 0.90) for patient satisfaction were recorded.

CONCLUSION

Late placed and early loaded implants with a moderately rough endosseal surface are a reliable option for rehabilitating partially edentulous patients. An implant survival rate of 100% and a prosthodontic success rate of 93.8% were observed. Patient satisfaction scores were high and peri-implant hard and soft tissues remained healthy. The study findings should be carefully interpreted because of the small sample.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology
04 Faculty of Medicine > School of Dental Medicine > Department of Oral Surgery and Stomatology
04 Faculty of Medicine > School of Dental Medicine

UniBE Contributor:

Molinero Mourelle, Pedro, Schimmel, Martin, Raabe, Clemens, Chappuis, Vivianne

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1708-8208

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

08 May 2024 11:29

Last Modified:

08 May 2024 11:39

Publisher DOI:

10.1111/cid.13333

PubMed ID:

38711297

Uncontrolled Keywords:

dental implant early loading hydrophilic implant surface implant crowns late implant placement

BORIS DOI:

10.48350/196598

URI:

https://boris.unibe.ch/id/eprint/196598

Actions (login required)

Edit item Edit item
Provide Feedback