Katsoulis, Joannis; Mericske, Regina; Enkling, Norbert; Katsoulis, Konstantinos; Blatz, Markus B. (2015). In vitro precision of fit of computer-aided designed and computer-aided manufactured titanium screw-retained fixed dental prostheses before and after ceramic veneering. Clinical oral implants research, 26(1), pp. 44-49. Wiley-Blackwell 10.1111/clr.12299
Text
clr12299.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (355kB) |
OBJECTIVE
To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing.
MATERIALS AND METHODS
Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests.
RESULTS
All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270).
CONCLUSIONS
Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology 04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Craniomaxillofacial Surgery 04 Faculty of Medicine > School of Dental Medicine > Department of Prosthodontics [discontinued] |
UniBE Contributor: |
Katsoulis, Joannis, Mericske, Regina, Enkling, Norbert, Katsoulis, Konstantinos |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
0905-7161 |
Publisher: |
Wiley-Blackwell |
Language: |
English |
Submitter: |
Caroline Dominique Zürcher |
Date Deposited: |
03 Apr 2014 08:33 |
Last Modified: |
05 Dec 2022 14:28 |
Publisher DOI: |
10.1111/clr.12299 |
PubMed ID: |
24289301 |
Uncontrolled Keywords: |
computer-aided designed and computer-aided manufactured fixed dental prosthesis, implant framework fit, implant-supported, passive fit, porcelain firing, precision of fit |
BORIS DOI: |
10.7892/boris.42657 |
URI: |
https://boris.unibe.ch/id/eprint/42657 |