Pilgrim, Thomas; Roffi, Marco; Tüller, David; Muller, Olivier; Vuillomenet, André; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Heg, Dik; Jüni, Peter; Windecker, Stephan (2014). Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: Rationale and design of the BIOSCIENCE trial. American Heart Journal, 168(3), pp. 256-261. Elsevier 10.1016/j.ahj.2014.06.004
|
Text
Pilgrim AmHeartJ 2014_manuscript.pdf - Accepted Version Available under License Publisher holds Copyright. Download (456kB) | Preview |
|
Text
Pilgrim AmHeartJ 2014.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (205kB) |
Background
Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents (DES) aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt chromium DES with silicon carbide coating releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) in an all-comers patient population.
Design
The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer SES or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least one lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary endpoint target lesion failure (TLF) is a composite of cardiac death, target-vessel myocardial infarction, and clinically-driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for non-inferiority, inclusion of 2,060 patients would provide 80% power to detect non-inferiority of the biodegradable polymer SES compared with the durable polymer EES at a one-sided type I error of 0.05. Clinical follow-up will be continued through five years.
Conclusion