Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: Rationale and design of the BIOSCIENCE trial

Pilgrim, Thomas; Roffi, Marco; Tüller, David; Muller, Olivier; Vuillomenet, André; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Heg, Dik; Jüni, Peter; Windecker, Stephan (2014). Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: Rationale and design of the BIOSCIENCE trial. American Heart Journal, 168(3), pp. 256-261. Elsevier 10.1016/j.ahj.2014.06.004

[img]
Preview
Text
Pilgrim AmHeartJ 2014_manuscript.pdf - Accepted Version
Available under License Publisher holds Copyright.

Download (456kB) | Preview
[img] Text
Pilgrim AmHeartJ 2014.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (205kB) | Request a copy

Background

Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents (DES) aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt chromium DES with silicon carbide coating releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) in an all-comers patient population.

Design

The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer SES or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least one lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary endpoint target lesion failure (TLF) is a composite of cardiac death, target-vessel myocardial infarction, and clinically-driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for non-inferiority, inclusion of 2,060 patients would provide 80% power to detect non-inferiority of the biodegradable polymer SES compared with the durable polymer EES at a one-sided type I error of 0.05. Clinical follow-up will be continued through five years.

Conclusion

The BIOSCIENCE trial will determine whether the biodegradable polymer SES is non-inferior to the durable polymer EES with respect to TLF.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Kardiologie
04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Kardiologie

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM)
04 Faculty of Medicine > Pre-clinic Human Medicine > Department of Clinical Research (DCR)

UniBE Contributor:

Pilgrim, Thomas, Heg, Dierik Hans, Jüni, Peter, Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services

ISSN:

0002-8703

Publisher:

Elsevier

Language:

English

Submitter:

Doris Kopp Heim

Date Deposited:

10 Oct 2014 21:52

Last Modified:

20 Feb 2024 14:17

Publisher DOI:

10.1016/j.ahj.2014.06.004

PubMed ID:

25173535

BORIS DOI:

10.7892/boris.53833

URI:

https://boris.unibe.ch/id/eprint/53833

Actions (login required)

Edit item Edit item
Provide Feedback