Zumstein, MA; Raniga, Sumit; Labrinidis, Agatha; Eng, Kevin; Bain, Gregory I; Moor, BK (2016). Optimal Lateral Row Anchor Positioning in Posterior-Superior Transosseous Equivalent Rotator Cuff Repair: A Micro-Computed Tomography Study. Orthopaedic journal of sports medicine, 4(11), p. 2325967116671305. Sage Publications 10.1177/2325967116671305

[img]
Preview
Text
2325967116671305.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (387kB) | Preview

BACKGROUND

The optimal placement of suture anchors in transosseous-equivalent (TOE) double-row rotator cuff repair remains controversial.

PURPOSE

A 3-dimensional (3D) high-resolution micro-computed tomography (micro-CT) histomorphometric analysis of cadaveric proximal humeral greater tuberosities (GTs) was performed to guide optimal positioning of lateral row anchors in posterior-superior (infraspinatus and supraspinatus) TOE rotator cuff repair.

STUDY DESIGN

Descriptive laboratory study.

METHODS

Thirteen fresh-frozen human cadaveric proximal humeri underwent micro-CT analysis. The histomorphometric parameters analyzed in the standardized volumes of interest included cortical thickness, bone volume, and trabecular properties.

RESULTS

Analysis of the cortical thickness of the lateral rows demonstrated that the entire inferior-most lateral row, 15 to 21 mm from the summit of the GT, had the thickest cortical bone (mean, 0.79 mm; P = .0001), with the anterior-most part of the GT, 15 to 21 mm below its summit, having the greatest cortical thickness of 1.02 mm (P = .008). There was a significantly greater bone volume (BV; posterior, 74.5 ± 27.4 mm(3); middle, 55.8 ± 24.9 mm(3); anterior, 56.9 ± 20.7 mm(3); P = .001) and BV as a percentage of total tissue volume (BV/TV; posterior, 7.3% ± 2.7%, middle, 5.5% ± 2.4%; anterior, 5.6% ± 2.0%; P = .001) in the posterior third of the GT than in intermediate or anterior thirds. In terms of both BV and BV/TV, the juxta-articular medial row had the greatest value (BV, 87.3 ± 25.1 mm(3); BV/TV, 8.6% ± 2.5%; P = .0001 for both) followed by the inferior-most lateral row 15 to 21 mm from the summit of the GT (BV, 62.0 ± 22.7 mm(3); BV/TV, 6.1% ± 2.2%; P = .0001 for both). The juxta-articular medial row had the greatest value for both trabecular number (0.3 ± 0.06 mm(-1); P = .0001) and thickness (0.3 ± 0.08 μm; P = .0001) with the lowest degree of trabecular separation (1.3 ± 0.4 μm; P = .0001). The structure model index (SMI) has been shown to strongly correlate with bone strength, and this was greatest at the inferior-most lateral row 15 to 21 mm from the summit of the GT (2.9 ± 0.9; P = .0001).

CONCLUSION

The inferior-most lateral row, 15 to 21 mm from the tip of the GT, has good bone stock, the greatest cortical thickness, and the best SMI for lateral row anchor placement. The anterior-most part of the GT 15 to 21 mm below its summit had the greatest cortical thickness of all zones. The posterior third of the GT also has good bone stock parameters, second only to the medial row. The best site for lateral row cortical anchor placement is 15 to 21 mm below the summit of the GT.

CLINICAL RELEVANCE

Optimal lateral anchor positioning is 15 to 21 mm below the summit of the greater tuberosity in TOE.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Orthopaedic, Plastic and Hand Surgery (DOPH) > Clinic of Orthopaedic Surgery

UniBE Contributor:

Zumstein, Matthias, Moor, Beat Kaspar

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2325-9671

Publisher:

Sage Publications

Language:

English

Submitter:

Lilianna Bolliger

Date Deposited:

26 Apr 2017 16:12

Last Modified:

05 Dec 2022 15:02

Publisher DOI:

10.1177/2325967116671305

PubMed ID:

27900336

Uncontrolled Keywords:

arthroscopy; rotator cuff; shoulder anatomy; surgery

BORIS DOI:

10.7892/boris.94787

URI:

https://boris.unibe.ch/id/eprint/94787

Actions (login required)

Edit item Edit item
Provide Feedback