Assessing the effectiveness of a 3-month day-and-night home closed-loop control combined with pump suspend feature compared with sensor-augmented pump therapy in youths and adults with suboptimally controlled type 1 diabetes: a randomised parallel study protocol.

Bally, Lia; Thabit, Hood; Tauschmann, Martin; Allen, Janet M; Hartnell, Sara; Wilinska, Malgorzata E; Exall, Jane; Huegel, Viki; Sibayan, Judy; Borgman, Sarah; Cheng, Peiyao; Blackburn, Maxine; Lawton, Julia; Elleri, Daniela; Leelarathna, Lalantha; Acerini, Carlo L; Campbell, Fiona; Shah, Viral N; Criego, Amy; Evans, Mark L; ... (2017). Assessing the effectiveness of a 3-month day-and-night home closed-loop control combined with pump suspend feature compared with sensor-augmented pump therapy in youths and adults with suboptimally controlled type 1 diabetes: a randomised parallel study protocol. BMJ open, 7(7), e016738. BMJ Publishing Group 10.1136/bmjopen-2017-016738

[img]
Preview
Text
e016738.full.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (714kB) | Preview

INTRODUCTION

Despite therapeutic advances, many individuals with type 1 diabetes are unable to achieve tight glycaemic target without increasing the risk of hypoglycaemia. The objective of this study is to determine the effectiveness of a 3-month day-and-night home closed-loop glucose control combined with a pump suspend feature, compared with sensor-augmented insulin pump therapy in youths and adults with suboptimally controlled type 1 diabetes.

METHODS AND ANALYSIS

The study adopts an open-label, multi-centre, multi-national (UK and USA), randomised, single-period, parallel design and aims for 84 randomised patients. Participants are youths (6-21 years) or adults (>21 years) with type 1 diabetes treated with insulin pump therapy and suboptimal glycaemic control (glycated haemoglobin (HbA1c) ≥7.5% (58 mmol/mol) and ≤10% (86 mmol/mol)). Following a 4-week run-in period, eligible participants will be randomised to a 3-month use of automated closed-loop insulin delivery combined with pump suspend feature or to sensor-augmented insulin pump therapy. Analyses will be conducted on an intention-to-treat basis. The primary outcome is the time spent in the target glucose range from 3.9 to 10.0 mmol/L based on continuous glucose monitoring levels during the 3-month free-living phase. Secondary outcomes include HbA1c at 3 months, mean glucose, time spent below and above target; time with glucose levels <3.5 and <2.8 mmol/L; area under the curve when sensor glucose is <3.5 mmol/L, time with glucose levels >16.7 mmol/L, glucose variability; total, basal and bolus insulin dose and change in body weight. Participants' and their families' perception in terms of lifestyle change, daily diabetes management and fear of hypoglycaemia will be evaluated.

ETHICS AND DISSEMINATION

Ethics/institutional review board approval has been obtained. Before screening, all participants/guardians will be provided with oral and written information about the trial. The study will be disseminated by peer-reviewed publications and conference presentations.

TRIAL REGISTRATION NUMBER

NCT02523131; Pre-results.

Item Type:

Journal Article (Further Contribution)

Division/Institute:

04 Faculty of Medicine > Department of Gynaecology, Paediatrics and Endocrinology (DFKE) > Clinic of Endocrinology, Diabetology and Clinical Nutrition

UniBE Contributor:

Bally, Lia Claudia

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2044-6055

Publisher:

BMJ Publishing Group

Language:

English

Submitter:

Andreas Melmer

Date Deposited:

01 Oct 2019 15:14

Last Modified:

05 Dec 2022 15:10

Publisher DOI:

10.1136/bmjopen-2017-016738

PubMed ID:

28710224

Uncontrolled Keywords:

artificial pancreas closed-loop type 1 diabetes

BORIS DOI:

10.7892/boris.111480

URI:

https://boris.unibe.ch/id/eprint/111480

Actions (login required)

Edit item Edit item
Provide Feedback