Devenoges, Laurent; Di Domenico, Gianni; Stefanov, André; Jallageas, Antoine; Morel, Jacques; Südmeyer, Thomas; Thomann, Pierre (2017). Measurement of the magnetic field profile in the atomic fountain clock FoCS-2 using Zeeman spectroscopy. Metrologia, 54(2), pp. 239-246. Institute of Physics Publishing IOP 10.1088/1681-7575/aa62d1
Text
measurement.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (1MB) |
We report the evaluation of the second-order Zeeman shift in the continuous atomic fountain
clock FoCS-2. Because of its continuous operation and geometrical constraints, the methods
used in pulsed fountains are not applicable. We use here time-resolved Zeeman spectroscopy to probe the magnetic field profile in the clock. Pulses of ac magnetic excitation allow us to spatially resolve the Zeeman frequency and to evaluate the Zeeman shift with a relative uncertainty smaller than 5×10⁻¹⁶.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
08 Faculty of Science > Institute of Applied Physics 08 Faculty of Science > Institute of Applied Physics > Lasers |
UniBE Contributor: |
Stefanov, André |
Subjects: |
600 Technology > 620 Engineering 500 Science > 530 Physics |
ISSN: |
0026-1394 |
Publisher: |
Institute of Physics Publishing IOP |
Language: |
English |
Submitter: |
Simone Corry |
Date Deposited: |
11 Jun 2018 11:02 |
Last Modified: |
05 Dec 2022 15:12 |
Publisher DOI: |
10.1088/1681-7575/aa62d1 |
BORIS DOI: |
10.7892/boris.114720 |
URI: |
https://boris.unibe.ch/id/eprint/114720 |