Effect of Increasing Stent Length on 3-Year Clinical Outcomes in Women Undergoing Percutaneous Coronary Intervention With New-Generation Drug-Eluting Stents: Patient-Level Pooled Analysis of Randomized Trials From the WIN-DES Initiative.

Chandrasekhar, Jaya; Baber, Usman; Sartori, Samantha; Stefanini, Giulio G; Sarin, Michele; Vogel, Birgit; Farhan, Serdar; Camenzind, Edoardo; Leon, Martin B; Stone, Gregg W; Serruys, Patrick W; Wijns, William; Steg, Philippe G; Weisz, Giora; Chieffo, Alaide; Kastrati, Adnan; Windecker, Stephan; Morice, Marie-Claude; Smits, Pieter C; von Birgelen, Clemens; ... (2018). Effect of Increasing Stent Length on 3-Year Clinical Outcomes in Women Undergoing Percutaneous Coronary Intervention With New-Generation Drug-Eluting Stents: Patient-Level Pooled Analysis of Randomized Trials From the WIN-DES Initiative. JACC. Cardiovascular Interventions, 11(1), pp. 53-65. Elsevier 10.1016/j.jcin.2017.11.020

[img] Text
2018 JACC Cardiovasc Interv_ Chandrasekhar.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (455kB) | Request a copy

OBJECTIVES

The aim of this study was to examine whether stent length per patient and stent length per lesion are negative markers for 3-year outcomes in women following percutaneous coronary intervention (PCI) with new-generation drug-eluting stents (DES).

BACKGROUND

In the era of advanced stent technologies, whether stent length remains a correlate of adverse outcomes is unclear.

METHODS

Women treated with new-generation DES in 14 randomized trials from the WIN-DES (Women in Innovation and Drug-Eluting Stents) pooled database were evaluated. Total stent length per patient, which was available in 5,403 women (quartile 1, 8 to 18 mm; quartile 2, 18 to 24 mm; quartile 3, 24 to 36 mm; quartile 4, ≥36 mm), and stent length per lesion, which was available in 5,232 women (quartile 1, 8 to 18 mm; quartile 2, 18 to 20 mm; quartile 3, 20 to 27 mm; quartile 4, ≥27 mm) were analyzed in quartiles. The primary endpoint was 3-year major adverse cardiovascular events (MACE), defined as a composite of all-cause death, myocardial infarction, or target lesion revascularization.

RESULTS

In the per-patient analysis, a stepwise increase was observed with increasing stent length in the adjusted risk for 3-year MACE (p for trend <0.0001), myocardial infarction (p for trend <0.001), cardiac death (p for trend = 0.038), and target lesion revascularization (p for trend = 0.011) but not definite or probable stent thrombosis (p for trend = 0.673). In the per-lesion analysis, an increase was observed in the adjusted risk for 3-year MACE (p for trend = 0.002) and myocardial infarction (p for trend <0.0001) but not other individual endpoints. On landmark analysis for late event rates between 1 and 3 years, stent length per patient demonstrated weak associations with target lesion revascularization (p = 0.0131) and MACE (p = 0.0499), whereas stent length per lesion was not associated with higher risk for any late events, suggesting that risk was established early within the first year after PCI.

CONCLUSIONS

In this pooled analysis of women undergoing PCI with new-generation DES, increasing stent length per patient and per lesion were independent predictors of 3-year MACE but were not associated with definite or probable stent thrombosis.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Windecker, Stephan, Valgimigli, Marco

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1876-7605

Publisher:

Elsevier

Language:

English

Submitter:

Amanda Valle

Date Deposited:

03 Aug 2018 16:51

Last Modified:

05 Dec 2022 15:17

Publisher DOI:

10.1016/j.jcin.2017.11.020

PubMed ID:

29301648

Uncontrolled Keywords:

new-generation drug-eluting stents patient-level pooled analysis of women percutaneous coronary intervention stent length per lesion stent length per patient

BORIS DOI:

10.7892/boris.119043

URI:

https://boris.unibe.ch/id/eprint/119043

Actions (login required)

Edit item Edit item
Provide Feedback