How Symmetrical Are Bony Orbits in Humans?

Lieger, Olivier; Schaub, Manuel; Taghizadeh, Elham; Büchler, Philippe (2019). How Symmetrical Are Bony Orbits in Humans? Journal of oral and maxillofacial surgery, 77(1), pp. 118-125. Elsevier 10.1016/j.joms.2018.08.018

[img] Text
1-s2.0-S0278239118309832-main.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (961kB)

PURPOSE

Establishing the symmetry of intraindividual orbital volumes is crucial for radiologic assessment, preoperative planning, and postoperative outcome evaluation. However, no reliable method exists to measure orbital volume because of problems in defining the bony boundaries of the orbit. Therefore, the purpose of this study was to propose a new approach to analyze human orbits and determine its application for quantifying bony symmetry in a cohort of patients.

PATIENTS AND METHODS

Computed tomography scans of 93 patients were retrospectively collected from our institutional database. The intraindividual volume difference was quantified using a surface model derived from manual segmentations. The average shape of the orbit was calculated iteratively and nonrigidly registered to both orbits of all patients. After registration, the surface reconstructions of all orbits had an identical mesh topology and vertices at corresponding anatomic locations. The volume difference was calculated locally based on the relative position of the vertices at equivalent locations in the left orbit and right orbit. This approach was used to quantify the volume difference between the left and right orbits for all patients. Interobserver sensitivity was assessed in 5 randomly chosen patients and was measured independently by 3 specialists.

RESULTS

An average difference of 600 ± 500 μL between the volumes of the left and right orbits was found, representing a difference of 2.1%. Although the difference in volume was small, the volumes were significantly different (P = .039). The largest asymmetries were found in the roof and floor area.

CONCLUSIONS

The method proposed to measure the difference in volume between the left and right orbits is automated and does not rely on a closed orbital volume, which provides more objective volume measurements. With the help of modern computed tomography techniques and the coherent point drift method, it was possible to show that the intraindividual volume difference in the orbits is approximately 2%, not 7 to 8% as often cited in the literature.

Item Type:

Journal Article (Original Article)

Division/Institute:

10 Strategic Research Centers > ARTORG Center for Biomedical Engineering Research > ARTORG Center - Computational Bioengineering
04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Craniomaxillofacial Surgery
10 Strategic Research Centers > ARTORG Center for Biomedical Engineering Research

UniBE Contributor:

Lieger, Olivier, Taghizadeh, Elham, Büchler, Philippe

Subjects:

500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health

ISSN:

0278-2391

Publisher:

Elsevier

Language:

English

Submitter:

Caroline Dominique Zürcher

Date Deposited:

15 Feb 2019 13:34

Last Modified:

26 Jun 2024 16:28

Publisher DOI:

10.1016/j.joms.2018.08.018

PubMed ID:

30243522

BORIS DOI:

10.7892/boris.123959

URI:

https://boris.unibe.ch/id/eprint/123959

Actions (login required)

Edit item Edit item
Provide Feedback